Whirlpool UXL5430BSS Manuel d'utilisation

Page 9

Advertising
background image

9

Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet. Mark the cutout as shown.
Use a saber saw or keyhole saw to cut a round opening
through the back of the cabinet and the exterior wall for the
vent.

Go to Step 3.

Non-Vented (recirculating) Installation Through the
Soffit/Cabinet

Measure and mark the centerline of the cabinet to the soffit
above.

Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5¾"
(14.6 cm) hole for the vent cover.

Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.

For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.

For non-vented (recirculating) installations, charcoal filters are
necessary. See the “Range Hood Care” section for
instructions on installing charcoal filters.

The Recirculation Kit Part Number W10490330 must be used.

A. Measurement A
B. Centerline

C. 6¼" (15.9 cm) round cutout

A. Vent cover
B. Centerline

B

A

C

A

B

A. Cutout
B. *See chart below.

C. 7

³⁄₄

" (19.7 cm) centerline to cabinet front

D. Centerline

Cabinet Height

Hole Shape and Size

12" (30.5 cm)

A 6¼" deep x 8" wide (15.9 cm x 20.3 cm)
rectangular opening in the cabinet top is
required for damper transition clearance.

15" (38.1 cm)
cabinet or soffit
installation

A 6¼" (15.9 cm) diameter round opening is
required.

18" (45.7 cm) or
24" (61.0 cm)

A 5¾" (14.6 cm) diameter round opening is
required.

D

A

B*