5. Mark Hole Locations

Lift the range hood into place and insert the mounting bracket
tabs through the slots in the back of the range hood.

Hold the range hood firmly in place with one hand and bend each
mounting tab (A) upward approximately 90°.

Mark the hole at the power supply knockout (B).

OPTIONAL: Mark the hole in each mounting tab.

Remove the range hood and set it aside.

6. Drill Electrical Opening

Using a 1

¹⁄₄" (3 cm) drill bit, drill the hole in the dot marked

previously at the electrical strain relief.

OPTIONAL: Using a

¹⁄₈" (3 mm) drill bit, drill pilot holes for the

dots marked previously at each mounting tab at an approximate
45° angle in an upward direction.

7. Prepare Range Hood Vents and

Mounting Tabs

Install Strain Relief

Install a UL Listed/CSA Approved

¹⁄₂" (13 mm) strain relief (A).

Mounting Tabs

Start a #8-18 x

⁵⁄₈" (4.2 x 16 mm) truss-head screw into the

mounting tab (C) on each side of the range hood as shown in
the inset. Insert the screws approximately 2 turns into the
mounting tab holes.

Non-vent (Recirculating) Installations

Remove the (2) T10

®†

Torx

®

screws and remove the top, front

rectangular vent cover (B).

B

A

90˚

A

B

x2

C