INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Parts supplied

Remove parts from package. Check that all parts are included.

Parts needed

Optional accessories

*For information on ordering, see the “Assistance or Service”

section.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the range hood on
the left wall.

Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.

This range hood is recommended for use with cooktops with
a maximum total rating of 40,000 BTUs or less.

Grounded electrical outlet is required. See “Electrical
Requirements” section.

All openings in ceiling and wall where range hood will be
installed must be sealed.

These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the “Assistance or
Service” section for information on ordering charcoal filters.

For Mobile Home Installations

The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.

Flat-blade
screwdriver

Drill with

¹⁄₈

" (3 mm),

¹⁄₂

" (13 mm),

and 1

¹⁄₄

" (3 cm) bits

Wire stripper

#2 Phillips
screwdriver

Pencil

#8-18 x

⁵⁄₈

"

(4.2 x 16 mm)
truss-head screws

#8-18 x 1"
(4.2 x 25 mm)
flat-head screws

Drywall
anchors

Mounting
brackets

UL Listed/CSA
Approved
wire connectors

UL Listed/CSA
Approved

¹⁄₂

" (13 mm)

strain relief

120V, 75W
maximum,
type E26
incandescent lamp

Charcoal
filter kit
Part Number
W10355450*

Power
cord kit
Part Number
W10355452*

Stainless steel
cleaner and
polish
Part Number
31462A*

Advertising