Warning – Napoleon Fireplaces EPI 1101 Manuel d'utilisation

Page 17

Advertising
background image

17

W415-0764 / C / 11.19.13

EN

!

WARNING

6.1 BLOWER

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to pre-
vent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy. Use of the blower increases the output of heat.

The 1402 inserts comes equipped with two blowers, while the 1101 has one blower. These blowers are ther-
mally activated. Depending on the intensity of the fi re, the blowers will start 15-30 minutes after lighting. The
heat sensor for the 1402 is located on the right hand side of the unit and the 1101 has a heat sensor located
at the back on the blower access door. When fi rst starting the fi re, the sensor may be impeded by a large log
or an unevenly burning fi re, causing the blowers to cycle on and off. To control this, either build your fi re up
evenly or turn down the blowers until the right side of the fi rebox is hot.

You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot,
it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the fi rebox
and secondary fl ames fl ickering just below the top fi rebrick. You can safely fi ll the fi rebox with wood to the top
of the door and will get best burns if you keep the appliance pipe temperatures between 250°F (120°C ) and
450°F (270°C ). A surface thermometer placed on the front top will help regulate this.

Without an appliance thermometer, you are working blindly and have no idea of how the appliance is operating!
An appliance thermometer offers a guide to performance.

Can’t get the fi re going?
Use more kindling and paper. Assuming the chimney and vent are sized correctly and there is suffi cient com-
bustion air, the lack of suffi ciently dry quantities of small kindling is the problem. Thumb size is a good gauge
for small kindling diameter.

Can’t get heat out of the appliance?
One of two things may have happened. The appliance door may have been closed prematurely and the appli-
ance itself has not reached optimum temperature. Reopen the door and/or draft control to re-establish a brisk
fi re. The other problem may have been wet wood. The typical symptom is sizzling wood and moisture being
driven from the wood.

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH

THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, ETC.)

COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

ENSURE THAT THE BLOWER’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE

APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER

CORD BENEATH THE APPLIANCE.

Advertising