SYMPTOM

PROBLEM

TEST SOLUTION

White / grey fi lm forms.

Sulphur from fuel is being
deposited on glass, logs or
combustion chamber surfaces.

-

Clean the glass with a recommended gas appliance
glass cleaner.

-

DO NOT CLEAN GLASS WHEN HOT.

-

If deposits are not cleaned off regularly, the glass may
become permanently marked.

Exhaust fumes smelled in
room, headaches.

Appliance is spilling.

-

Ensure exhaust bracket gasket seal.

-

Check door seal and relief fl ap seal.

-

Check for chimney blockage.

-

Check that chimney is installed to building code.

-

Room is in negative pressure; increase fresh air supply.

-

Check cap gasket on the fl ue pipe assembly.

Remote wall switch is in
’OFF’ position; main burner
comes on when gas knob
is turned to ‘ON’ position.

Wall switch is mounted upside down.

-

Reverse.

Remote wall switch is grounding.

-

Replace.

Remote wall switch wire is grounding.

-

Check for ground (short); repair ground or replace wire.

Faulty valve.

-

Replace.