Sample, 3 general information, 4 rating plate information – Napoleon Fireplaces GSS36 Manuel d'utilisation

Page 5: Rates and efficiencies

Advertising
background image

5

W415-0807 / B / 04.18.12

2.3 GENERAL

INFORMATION

* When the appliance is installed at elevations above 2,000ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.

It is highly recommended to protect the logs from moisture (rain, snow). Cover the enclosure opening when not
in use.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.

No external electricity (110 volts or 24 volts) is required for the gas system operation.

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!

RATES AND EFFICIENCIES

NATURAL GAS

PROPANE GAS

Altitude

0 - 2,000*

0 - 2,000*

Maximum Input

40,000 BTU/hr

40,000 BTU/hr

Minimum Inlet Gas Supply Pressure

4.5” Water Column

11” Water Column

Maximum Inlet Gas Supply Pressure

7” Water Column

13” Water Column

Manifold Pressure Under Flow Conditions

3.5” Water Column

10” Water Column

2.4 RATING PLATE INFORMATION

GSS36/CSS36

W385-0275 / J

CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: CGA CR97-003 (July, 1997) CSA US Req. 4-96, 3rd Ed. OUTDOOR GAS FIREPLACE / FOYER AU GAZ EXTÉRIEUR

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, IT MUST BE USED. THE
GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SYPPLY CYLINDER WHEN THIS APPLIANCE IS
NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S MANUAL PROVIDED
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUST NOT BE USED FOR
COOKING. FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH AND LEAVE CYLINDER
OUTDOORS.

SI L’APPAREIL EST ÉQUIPÉ D’UN RÉGULATEUR DE PRESSION D’ALIMENTATION, IT DOIT ÊTRE
UTILISÉ. LORSQUE CET APPAREIL N’EST PAS UTILISÉ, VOUS DEVEZ FERMER L’ALIMENTATION EN

GAZ SUR LA BONBONNE DE PROPANE. N’ENTREPOSEZ PAS ET N’UTILISEZ PAS D’ESSENCE
OU AUTRES LIQUIDES ET VAPEURS INFLAMMABLES À PROXIMITÉ DE CET APPAREIL OU
TOUT AUTRE APPAREIL. UNE INSTALLATION NON CONFORME, DES AJUSTEMENTS, DES
ALTÉRATIONS, UN SERVICE OU UN ENTRETIEN INADÉQUATS PEUVENT CAUSER DES
DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES CORPORELLES. RÉFÉREZ-VOUS AU
MANUEL D’INSTRUCTIONS FOURNI AVEC CET APPAREIL. POUR DE L’ASSISTANCE OU POUR
PLUS D’INFORMATION, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE AGENCE
D’ENTRETIEN OU LE FOURNISSEUR DE GAZ. NE PAS UTILISER POUR LA CUISSON. POUR
USAGE EXTÉTIEUR SEULEMENT. SI ENTREPOSÉ À L’INTÉRIEUR, DÉTACHER LA BONBONNE

DE PROPANE ET LA LAISSER À L’EXTÉRIEUR.

9700539 (WSL)

4001657 (NGZ)

4001658

(NAC)

4001659

(WUSA)

GSS36N / CSS36N

MODEL

GSS36P / CSS36P

0-4500FT (0-1370m)

ALTITUDE / ÉLÉVATION

0-4500FT (0-1370m)

40,000 BTU/h

INPUT / ALIMENTATION

40,000 BTU/h

20,000 BTU/h

REDUCED INPUT / ALIMENTATION RÉDUITE

22,000 BTU/h

MANIFOLD PRESSURE: 3.5" WATER COLUMN

MANIFOLD PRESSURE: 10" WATER COLUMN

PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU

PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN

PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU

PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU

PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU

NOT FOR USE WITH SOLID FUEL.

WARNING:

THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.

REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP 0”

BACK

0”

FLOOR 0“

MANTEL

12”*

SIDES 0”

RECESSED

DEPTH

13

1

/

2

*MAXIMUM HORIZONTAL EXTENSION: 2”.
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.

UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ

AVEC CET APPAREIL

AVERTISSEMENT:

CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION

RAPIDE. REPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL
LTÉE. N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.

DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
DESSUS 0”

ARRIÈRE

0”

PLANCHER 0“

MANTEAU

12”*

CÔTÉS 0”

PROFONDEUR

D’ENCASTRE

13

1

/

2

*L’EXTENSION HORIZONTALE MAXIMALE: 2”.
RÉFÉRER AU MANUEL D’INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.

SERIAL NUMBER/NO. DE SÉRIE:

J

J

SAMPLE

SAMPLE

OOR GAS

OOR GAS

ON, L4M 0G8

ON, L4M 0G8

PÉ D’UN RÉGU

PÉ D’UN RÉG

ET APPAREIL N’EST PA

T APPAREIL N’EST

A

BONBONNE DE PROPANE

ONBONNE DE PROPA

S LIQUIDES ET VAPEURS INF

LIQUIDES ET VAPEURS INF

UTRE APPAREIL. UNE INSTALLATI

APPAREIL. UNE INSTALLATI

RATIONS, UN SERVICE OU UN EN

UN SERVICE OU UN EN

MMAGES À LA PROPRIÉTÉ OU DES

PROPRIÉTÉ OU DES

MANUEL D’INSTRUCTIONS FOURNI AV

ANUEL D’INSTRUCTIONS FOURNI A

PLUS D’INFORMATION, CONSU

PLUS D’INFORMATION, CONSU
D’ENTRETIEN OU LE FOURNISS

D’ENTRETIEN OU LE FOURNISS
USAGE EXTÉTIEUR SEULEME

USAGE EXTÉTIEUR SEULEME

4001657 (NGZ)

4001657 (NGZ)

4001659 (WUSA)

001659 (WUSA)

PL

PL

MODEL

MODEL

GSS

GSS

LTITUDE / ÉLÉVATION

TITUDE / ÉLÉVATION

0-

0

INPUT / ALIMENTATION

PUT / ALIMENTATION

CED INPUT / ALIMENTATION RÉDUITE

ED INPUT / ALIMENTATI

PL

ATER COLUMN

ATER COLU

MANIFOLD PRE

MANIF

COLONNE D'EAU

COLONNE D'EA

PRESSION A

PRESSIO

.5" WATER COLUMN

WATER COLUMN

MINIMUM

MINIMUM

'UNE COLONNE D'EAU

UNE COLONNE D'EAU

PRESSI

RESS

RE:

RE: 7.0" WATER COLUMN

7.0" WATER COLUMN

MAXI

7.0" D'UNE COLONNE D'EAU

.0" D'UNE COLONNE D'EAU

PR

P

UEL.

EL.

ST ACTING THERMOCOUPLE.

T ACTING THERMOCOUPLE.

PPLIED BY WOLF STEEL LTD.

PPLIED BY WOLF STEEL LTD.

WILL COME

LL COME IN CONTACT WITH THE

IN CONTACT WITH THE

FACTURER WITH THE APPLIANCE.

RER WITH THE APPLIANCE.

ALS:

SSED DEPTH

SED DEPTH

2”.

TER EXTENSIONS.

ER EXTENSIONS

For rating plate location, see “INSTALLATION OVERVIEW” section.

This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

Advertising