Put power supply cord through the strain relief. Be sure

that the wire insulation on the power supply cord is inside

the strain relief. The strain relief should have a tight fit with

the dryer cabinet and be in a horizontal position. Do not

further tighten strain relief screws at this point.

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any

screws from a " (19 mm) UL listed strain relief (UL

marking on strain relief). Put the threaded section of the

strain relief through the hole below the terminal block

opening. Reaching inside the terminal block opening,

screw the removable conduit connector onto the strain

relief threads.

Put direct wire cable through the strain relief. The strain

relief should have a tight fit with the dryer cabinet and be

in a horizontal position. Tighten strain relief screw against

the direct wire cable.

4. Now complete installation following instructions for your type

of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)

Electrical Connection Options

*If local codes do not permit the connection of a cabinet-ground

conductor to the neutral wire, go to “Optional 3-wire connection”

section.

4-wire connection: Power Supply Cord

IMPORTANT: A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire

connections.

A. Removable conduit connector
B. Hole below terminal block opening

C. Strain relief threads

A

B

C

If your home has:

And you will be

connecting to:

Go to Section

4-wire receptacle

(NEMA Type 14-30R)

A UL listed,

120/240-volt

minimum,

30-amp, dryer

power supply

cord*

4-wire connection:
Power supply cord

4-wire direct

A fused

disconnect or

circuit breaker

box*

4-wire connection:
Direct Wire

3-wire receptacle

(NEMA type 10-30R)

A UL listed,

120/240-volt

minimum,

30-amp, dryer

power supply

cord*

3-wire connection:
Power supply cord

3-wire direct

A fused

disconnect or

circuit breaker

box*

3-wire connection:
Direct Wire

A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug

C. Ground prong
D. Neutral prong

E. Spade terminals with upturned ends
F. ¾" (19 mm) UL listed strain relief

G. Ring terminals

(127 mm)

5"

(89 mm)

3 "

A

B

C

D

E

F

G

3

4

1

2