Installation Clearances

The location must be large enough to allow the dryer door to open

fully.
Dryer Dimensions

*Most installations require a minimum 5" (127 mm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting

Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this

dryer. This dryer has been tested for spacing of 0" (0 mm)

clearance on the sides and rear. Recommended spacing should

be considered for the following reasons:

Additional spacing should be considered for ease of

installation and servicing.
Additional clearances might be required for wall, door,

and floor moldings.
Additional spacing should be considered on all sides of the

dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

Companion appliance spacing should also be considered.

*Required spacing

Mobile Home - Additional Installation Requirements

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part 3280

(formerly the Federal Standard for Mobile Home Construction and

Safety, Title 24, HUD Part 280) or the Canadian Manufactured

Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:

Metal exhaust system hardware, which is available for

purchase from your dealer.
Special provisions must be made in mobile homes to

introduce outside air into the dryer. The opening (such as a

nearby window) should be at least twice as large as the dryer

exhaust opening.

Electrical Requirements - U.S.A.

It is your responsibility

To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in

conformance with the National Electrical Code, ANSI/NFPA

70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire supply

connection for homes built after 1996, dryer circuits involved

in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:

National Fire Protection Association, One Batterymarch Park,

Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt

electrical supply, if specified on the serial/rating plate) on a

separate 30-amp circuit, fused on both sides of the line. A

time-delay fuse or circuit breaker is recommended. Connect

to an individual branch circuit. Do not have a fuse in the

neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is

recommended that a qualified electrician determine that the

ground path is adequate.

A. Small opening side-swing door
B. Large opening side-swing door

C. Wide opening side-swing door
D. Wide opening hamper door

43 "

(1102 mm)

*26"

(660 mm)

29"

(737 mm)

A

15¼"

(387 mm) 43 "

(1102 mm)

*27¾"

(705 mm)

29"

(737 mm)

B

22¾"

(578 mm)

43 "

(1102 mm)

13¾"

(349 mm)

*27¾"

(705 mm)

29"

(737 mm)

D

43 "

(1102 mm)

*27¾"

(705 mm)

29"

(737 mm)

C

22¾"

(578 mm)

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

A

B

C

18"*

(457 mm)

1"

(25 mm)

29"

(737 mm)

1"

(25 mm)

1"*

(25 mm)

14" max.*

(356 mm)

27¾"

(705 mm)

5"*

(127 mm)

48 in.

(310 cm )

2

*

2

24 in.

(155 cm )

2

*

2

3"*

(76 mm)

3"*

(76 mm)

3

8

3

8

3

8

3

8