36

5

ConstruCtion, layout & Controls

automatically set once a particular battery type corresponding to one of the 8 options has

been programmed using DIP Switches 2,3,4 (See page 43, Table 6.1).
SCREEN 7: Displays the heat sink temperature (Heatsink) in °C (the metal plate of the front

panel acts as the heat sink). It also displays the temperature of the battery in °C when the

optional Battery Temperature Sensor (BTS) Model No. DC-BTS-A-C is used.

NOTE: The battery temperature can not be displayed below 0°C. If the battery
temperature falls below 0°C, the display will read “- - - °C”.

Amp Watts BatV

0.0

0.0

12.0

Amp-Hours

0 Ah

Total Amp-Hours

0 Ah

Mode: Charger

State: Bulk or Absorption or

Float or Equalization

Bulk*

Float

14.0V

13.4V

EQU EQU-T CYCLE

14.2V

1hr

28day

Heatsink BTS

25oC

25oC

PUSH: Display Select

PUSH: Display Select

PUSH: Display Select

PUSH: Display Select

PUSH: Display Select

PUSH: Display Select

PUSH: Display Select

Display Screens (1, Fig 5.1)

Screen 1

Screen 2

Screen 3

Screen 4

Screen 5

Screen 6

Screen 7

* Note: Displayed as “Bulk”.

Actually, it is “Absorption”.

Fig. 5.3. LCD Display Flow