Exemple de commande/réponse – HP Baie modulaire Smart Array HP StorageWorks 1000 Manuel d'utilisation

Page 20

Advertising
background image

20

Utiliser l'interface CLI

Exemple de commande/réponse show version -all

Exemple de commande/réponse show this_controller

CLI> show this_controller

Controller 1 (right controller):

MSA1500 c Hewlett-Packard xxx Version 6.86 Build 122 Hardware 7

Component Enclosure.

Controller Identifier:

NODE_ID=yyyyyyyy-yyyyyyyy

SCSI_VERSION=SCSI-3

Supported Redundancy Mode: Active/Standby Asm-Active/Active

Current Redundancy Mode: Asym-Active/Active

Device Port SCSI address 6

Terminal speed for the CLI is set to 19200.

Host Port_1:

REPORTED PORT_ID YYYYYYYYY-YYYYYYYYY

PORT_1_TOPOLOGY=F_Port

Cache:

128 megabytes read cache 128 megabytes write cache Version 2

Cache is GOOD, and Cache is enabled

No unflushed data in cache

Battery:

Module #1 is fully charged and turned off.

Controller Up Time:

5 Days 06 Hours 01 Minutes 51 Seconds

Health:

Surface Scan:

Complete.

Rebuild Status: Complete.

Expansion:

Complete.

CLI> show version -all

MSA 1500 Firmware Revision:

5.10b414 (SGA0434084)

MSA 1500 Firmware Revision:

7 [AutoRev: 0x010000]

Fibre Module AutoRev:

0x020000

SCSI I/O Module Bus 0 Revision:

2.02

SCSI I/O Module Bus 1 Revision:

2.02

SCSI I/O Module Bus 2 Revision:

2.02

SCSI I/O Module Bus 3 Revision:

2.02

Fan Control Module A Revision:

2.38

Fan Control Module B Revision:

2.38

Box 1a PROLIANT 4L7E*DB Rev:

Box 1b PROLIANT 4L7E*DT Rev:

Box 3b PROLIANT 4L7E*DT Rev:

Box 3a PROLIANT 4L7E*DB Rev:

2.30 (Z8LCLMPY47)

CP20 (Z8LCLMPY47)

CP20 (TERJE2BOX2)

2.30 (TERJE2BOX2)

Disk Drives:

B T L BOX BAY GB Model

Rev.

Serial No.

0 0 0 1

1

146.8 COMPAQ

BD146863B3

HPB8 B8LX86HM

0 0 0 1

1

146.8 COMPAQ

BD146863B3

HPB8 B8LX8EFM

0 8 0 1

7

146.8 COMPAQ

BD14686225

HPB6 P01P4707AGE0431

Advertising
Ce manuel est liée aux produits suivants: