Utiliser l'interface CLI

Exemple de commande/réponse show disks pour un MSA1500

Exemple de commande/réponse show unit #

CLI> show disks

Disk List:

(box,bay)

(B:T:L:)

Size

Speed

Units

Enclosure 1: SATA

SATA

PROLIANT 8LCE

Disk101

(1,01)

(0:03:01)

250.0GB

160 MB/s

none

Disk102

(1,02)

(0:03:02)

250.0GB

160 MB/s

none

Disk103

(1,03)

(0:03:03)

250.0GB

160 MB/s

none

Disk104

(1,04)

(0:03:04)

250.0GB

160 MB/s

none

Disk105

(1,05)

(0:03:05)

250.0GB

160 MB/s

none

Disk106

(1,06)

(0:03:06)

250.0GB

160 MB/s

none

Disk107

(1,07)

(0:03:07)

250.0GB

160 MB/s

none

Enclosure 2: SCSI

PROLIANT

PROLIANT 4LEE

Disk201

(2,01)

(1:00:00)

250.0GB

160 MB/s

none

Disk202

(2,02)

(1:01:00)

250.0GB

160 MB/s

none

Disk203

(2,03)

(1:02:00)

250.0GB

160 MB/s

none

Disk204

(2,04)

(1:03:00)

250.0GB

160 MB/s

none

Disk205

(2,05)

(1:04:00)

250.0GB

160 MB/s

none

Disk206

(2,06)

(1:05:00)

250.0GB

160 MB/s

none

CLI> show unit 1

Unit 1:

In PDLA mode, Unit 1 is LUN 2; In VSA mode, Unit 1 is LUN 1

Unit Identifier:

Device Indentifier:

600805F3-00006B20-AE277D4B-B0D100F7

Preferred Path:

Controller 1 (this controller)

Cache Status:

Enabled

Max Boot Partition:

Disabled

Volume Status:

VOLUME OK

Parity Init Status:

3% complete

5 Data Disk(s) used by lun 1:

Disk107:

Box 1, Bay 07, (B: T: L: 2;04:07)

Disk108:

Box 1, Bay 08, (B: T: L: 2;04:08)

Disk207:

Box 2, Bay 07, (B: T: L: 2;04:07)

Disk208:

Box 2, Bay 08, (B: T: L: 2;04:08)

Spare Disk(s) used by lun 1:

No spare drive is designated

Logical Volume Raid Level:

DISTRIBUTED PARITY FAULT TOLERANCE

(RAID5)

stripe_size=16KB

Logical Volume Capacity:

173,658MB

Advertising