6.7 DATAFIELD 7

=#7500 //RW float

ACCES MODE 7

=#0 //0,1: 0=NORMAL 1=REVERSED DATATYPE

-------------------------------------------------------------------------------------------------------------------------------------------
7<MODBUS MASTER POLLBLOCK DEFINITION>
7.1 NUMBER_OF_POLLBLOCKS_TO_USE

=#1

//1..20 NUMBER OF POLLBLOCKS TO TRANSMIT

7.2 REQUEST_TO_RESPONSE_TIMOUT

=#10

//35 ms units


POLLBLOCK:
SLAVEID

- MODBUS SLAVE ADDRESS, 0..247

MASTERREGISTER

- ADDRESS OF DATA IN ALTOSONIC_V, 0..10000

SLAVEREGISTER

- ADDRESS OF DATA IN SLAVE, 0..10000

N_POINTS

- NUMB OF DATA ITEMS TO TRANSFER(NOT REGISTERS BUT DATATYPES)0..255

FUNCTION

- FUNCTION TO USE FOR DATA TRANSFER,1..16

DATATYPE

- DATATYPE FOR CODING,DECODING AND VERIFICATION

1=boolean

2=integer

3=longinteger

4=float

5=double

DATANOTATION

- NORMAL(0) OR REVERSED NOTATION(1) OF THE DATATYPE

DELAY

- DELAY TO TRANSMIT NEXT POLLBLOCK 1..30000


7.3
NR

SLAVEID MASTERREG. SLAVEREG. N_POINTS FUNC DATATYPE DATANOT. DELAY

1

#1

#2000

#7501

#2000

#1 #1

#0 #5

2

#1

#3010

#3501 #10

#3 #2

#0 #5

3

#1

#7010

#7501 #10

#3 #4

#0 #5

4

#1

#5010

#5501 #10

#3 #3

#0 #5

5

#1

#7018

#7501 #2

#3 #4

#0 #5

6

#0

#0

#0 #1

#1 #1

#0 #1

7

#0

#0

#0 #1

#1 #1

#0 #1

8

#0

#0

#0 #1

#1 #1

#0 #1

9

#0

#0

#0 #1

#1 #1

#0 #1

10

#0

#0

#0 #1

#1 #1

#0 #1

11

#0

#0

#0 #1

#1 #1

#0 #1

12

#0

#0

#0 #1

#1 #1

#0 #1

13

#0

#0

#0 #1

#1 #1

#0 #1

14

#0

#0

#0 #1

#1 #1

#0 #1

15

#0

#0

#0 #1

#1 #1

#0 #1

16

#0

#0

#0 #1

#1 #1

#0 #1

17

#0

#0

#0 #1

#1 #1

#0 #1

18

#0

#0

#0 #1

#1 #1

#0 #1

19

#0

#0

#0 #1

#1 #1

#0 #1

20

#0

#0

#0 #1

#1 #1

#0 #1

-------------------------------------------------------------------------------------------------------------------------------------------