Shutdown, Temperature settings – CAMPO EQUIPMENT BLAZE 150E Manuel d'utilisation

Page 8

Advertising
background image

8

Turn on heater settings as desired

(150kW= 60kW & 90kW combined)

CAUTION;

Failure to have proper air flow will cause heater to shut

down, it is imperative to maintain proper air flow.

NOTE:

The red light should come on and air should be pushed through the outlet

port. Check to see that only the red light is on.


Variable Speed Drive is pre-set for optimum air flow/
temperature rise. Based on “Heat Setting” selection, blower
will adjust speed. See Chart below:


TEMPERATURE SETTINGS

HEAT SETTING

BTU/Hr.

CFM

TEMP.RISE

150kW

512,000

14,500

220F+

90kW

307,000

10,000

220F+

60kW

205,000

7,000

180F

FAN ONLY

0

14,500

N/A

SHUTDOWN

1

Move heat ON/OFF control setting to the "OFF" position

2

When cooling fan shuts down you may shut off power source

3

Shut off power source

4

Disconnect all power sources

5

Store heater





8

Advertising