Electrical – CAMPO EQUIPMENT MOFH280400 Manuel d'utilisation

Page 6

Advertising
background image

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)

6 Carson Court, Brampton, ON, CANADA, L6T 4P8

Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com

@100 PSI SETTING: 21 HRS

@ 125 PSI SETTING: 19 HRS
@ 150 PSI SETTING: 17 HRS
@ 200 PSI SETTING: 15 HRS


CONNECTING TO AN EXTERNAL FUEL TANK
(MOFH280400)

Beckett CF375 is fitted with 3/8” SAE male fittings and is set up for a 2 line system to eliminate
priming. Ensure fuel tank has an supply line and a return line and connect the supply line to the
3/8” SAE fitting on the inlet side of the fuel filter and the return line to the return fitting located on
the Beckett Burner pump. For a 1 line system remove bypass plug located on inlet port of Beckett
Pump and just connect fuel line to inlet side of fuel filter.

ELECTRICAL

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE

120V SUPPLY MUST BE AVAILABLE.

INSTALLATION

• 12/3 AWG UPTO 50FT

• 10/3 AWG BEYOND 50FT


NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.


ELECTRICAL SYSTEM

MOFH280400

Volts-Hertz-Phase

120-60-1

Full Load (Amps) (1PH)

14.4

Max fuse size (Amps) (1PH)
with time delay

2


The electrical grounding of the heater shall be in compliance with the National Electrical Code, ANSI/NFPA
70, or the CSA C22.1, Canadian Electrical Code, Part I



Advertising