GROUND OR WALL INSTALLATION

2. Fasten the bracket with the track bolts. NOTE: Always use a fl at

washer next to the radius slot. Putting track bolts in slots will
prevent brackets from pivoting.

3. Attach the bracket assembly to the wall with lag screws

(provided) or to the ground with concrete anchors (not
provided).

4. Insert the sensor into the brackets and fasten with the hex

mounting nut and lock washer.

DOOR TRACK INSTALLATION (FOR GARAGE DOOR ONLY)

2. Drill 1/4" holes in each track and securely fasten the bracket

with the track bolts. NOTE: Always use a fl at washer next to the
radius slot. To vertically attach to 2 x 4 wall stud it may become
necessary to rotate bracket to prevent wood from splitting.

3. Insert the sensor into the bracket and fasten with the hex

mounting nut and lock washer.

The brackets can be mounted on the ground, door track, or wall.
Refer to examples shown below.
1. Determine the confi guration for your brackets. The assembly of

the brackets will vary depending on your installation.

INSTALL MODEL CPS-UN4

ASSEMBLE AND MOUNT THE BRACKETS

Make sure the brackets are aligned so the photoelectric sensors
will face each other across the entrapment zone.
FOR DOORS
Mount sensors no more than 6" (15 cm) above the fl oor and at a
width between 7'-45'.
FOR GATE
Mount within 5" (12.7 cm) of the moving
gate panel with a maximum height of 27.5"
(69.8 cm) above grade (21" (53.3 cm) is
recommended) and at a width between
7'-45'.
The recommended mounting location is on
the inside of the gate.

Assemble to either side

1/2" Hole Spacing

2" Hole Spacing

Flip one bracket and
assemble to either side

Assemble to either side

Flip one bracket and

assemble to either side

1/2" Hole Spacing

2" Hole Spacing

BRACKET ASSEMBLY CONFIGURATIONS

1/4" Flat Washer
1/4" Lock Washer
1/4"-20 Hex Nut

1/4" x 1-1/2"
Lag Screws

1/4"-20 x 5/8"
Track Bolts

1/4"-20 x 5/8"
Track Bolts

Lock Washer for Sensor

Hex Mounting Nut
for Sensor

1/4"-20x5/8"

Track Bolts

1/4" Flat Washer

1/4" Lock Washer

1/4" Hex Nut

1/4" Lock Washer

1/4"-20 Hex Nut

1/4"-20x5/8" Track Bolts

Lock Washer

Hex Mounting Nut

TYPICAL INSTALLATION

1/4" Flat Washer
1/4" Lock Washer
1/4"-20 Hex Nut

/4" Drill

oles

Door

1/4" Lock Was
1/4"-20 Hex N

Lock Washer for Sensor

Hex Mounting Nut
for Sensor

Hex Mounting Nut

Lock Washer

1/4" Flat Washer

1/4" Lock Washer

1/4" Hex Nut

1/4" Lock Washer
1/4"-20 Hex Nut

1/4"-20x5/8" Track Bolts

1/4" Drill

Holes

Door Track

TYPICAL INSTALLATION

GARAGE DOOR

Photoelectric

Sensor

Photoelectric

Sensor

GATE

5" (12.7 cm) max. gap

Edge of Gate Panel

Invisible Light Beam

Photoelectric

Sensor

Photoelectric

Sensor

Mounting

Post

Wall or Fence

27.5" (69.8 cm)

max.

6"

(15 cm)

6"

(15 cm)

Advertising