INSTALLATION INSTRUCTIONS

ECOS Housing

Rough-In Section 4 & 6

Upon receipt, thoroughly inspect for any
freight damage which should be brought
to the attention of the delivery carrier.
Compare the catalog description listed
on the packing slip with the label on the
carton to ensure that you have received
the correct merchandise.

IMPORTANT

INSTALLATION/WARRANTY

INFORMATION

For Your Protection, Read Carefully.
Luminaire should be installed in
applications

where

ambient

temperatures do not exceed 50°C.
Ambient temperatures that exceed
50°C will result in reduced life,
lumen output and will void warranty.

Warning: Risk of fire. Do not install
insulation within 3 inches of fixture
sides or wiring compartment, nor above
fixture in such a manner as to entrap
heat.

Electric current can cause painful
shock or serious injury unless
handled properly. For you safety,
always remember the following:

Turn off the supply power.

Ground the fixture to avoid
potential electrical shocks.

Do not handle an energized
fixture or energize any fixture with
wet hands, when standing on a
wet or damp surface, or in water.

SAVE THESE INSTRUCTIONS

PRIOR TO INSTALLATION
Read and familiarize yourself with the nomenclature
and instructions before starting installation.
Turn off electricity at the breaker panel or fuse box
and follow National Electrical Code regulations.

* WOOD OR STEEL JOIST CONSTRUCTION
On 24” centers utilizing solid type (non-

accessible) ceiling (drywall, plaster, etc.).
Note: 4” fixtures acceptable for use in 16” O.C.

USING ROUTER FOR CEILING CUTOUT
1. Open lever (C) securing bar hangers - bend

ends of hangers 90°(D) to be used as nailing

tabs, center in the vertical slot, and close
lever (C) to lock; repeat on opposite side.

(See Figure 1)

2. Secure a piece of plywood (E) to temporarily

span the bottom of the joists to support the

fixture housing while attaching the bar
hangers (F) to the joists. This will position the
housing correctly for drywall installer to

provide pilot hole (G) to locate fixture after
ceiling has been installed. (See Figure 2)

3. PROCEED TO “FEED WIRE CONNECTION

TO FIXTURE J-BOX” ON NEXT PAGE. (See
Figure 5)
Return and complete following

steps after feed wire connections have been
made.

4. Using 1/8” router follow outside of plaster

frame to cut hole in ceiling.

5. Loosen (2) 5/16” screws (A) 180° apart,

allowing fixture to drop down so bottom edge
of plaster flange will be slightly above edge of
ceiling material.






CJ520180 Rev. C

11/2013 2 of 8

©2008, 2010 Acuity Brands Lighting, Inc.

All Rights Reserved

T-BAR CEILING INSTALLATION
1. Install ceiling panel in t-bar with ceiling

opening precut. Ceiling opening must be
slightly larger than the outside diameter of the

plaster flange.

2. Open lever (A), expand bar hangers (B) to

approximately 24” and close lever to lock.

(See Figure 3)

3. Through an adjacent opening, position the

mounting frame with the plaster flange

passing through the precut opening with the
notches on the bar hangers engaging the t-

bar.

4. Secure the bar hangers to the t-bar by wire or

wiretie (by others) or bending end of bar

hanger. (See Figure 4)

5. Open lever and adjust mounting frame

vertically so that the bottom edge of the
plaster flange is flush or slightly above the
bottom edge of the ceiling panel.

6. PROCEED TO “FEED WIRE CONNECTION

TO FIXTURE J-BOX” ON NEXT PAGE.

(See Figure 5)

7. If fine tune adjustment from below ceiling is

required: Loosen (2) 5/16” screws (A) 180°

apart, allowing fixture to drop down so bottom
edge of plaster flange will be slightly above
edge of ceiling material.

C

D

B

A

E

F

G

Figure 1

Figure 2

Figure 3

Figure 4

*NOTE: For non-accessible
ceilings, a minimum of 9”
above fixture required to
remove dome assembly.