Routine maintenance

Soot and ash on the inside walls of the boiler and on the refractory bricks reduces the transfer of heat. However, during
the operation of a boiler with wood gasification less ash is produced than during heating with conventional boilers.

Remove the ash from the combustion chamber every 1-2 days, and in any case before it is full, so as to leave sufficient
space for combustion.

B

If the ash is still hot, use protective gloves.

Put the ash in a non-flammable container provided with a lid.

Carry out thorough cleaning at least once a week:

Open the loading door and brush the combustion residuals in the ash compartment through the opening between
the burner plates.

Clean the inside walls of the combustion chamber with a brush

Remove the loose soot and ash from the combustion chamber.

Check perfect door closure seal. Also make sure there is no tar or condensate dripping from the smokebox.

B

Do not clean the burner plates with a wire brush, as they may become damaged.

Extraordinary maintenance

Clean the fume ducts once a month:

Remove the top cover of the casing

Open the inspection door at the back of the boiler (see fig. 6).

Remove the turbulators and clean the fume ducts with a tube brush.

fig. 6 - Fume duct cleaning