English – Wells HDHP-1230G Manuel d'utilisation

Page 14

Advertising
background image

ENGLISH

TROUBLESHOOTING

12

226

306

627

OpM

anual

fo

r HDHP-Series Hot Pla

tes

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Pilot will not light

Gas supply off

Check main / unit gas valves

Air in lines

Turn pilot valve on. Attempt to
light pilot every 15 sec.

Pilot valve not on

Turn pilot valve on / adjust

Burners won’t light

Gas supply off

Check main / unit gas valves

Air in lines

Turn gas valve on. Attempt to
light pilot every 15 sec.

Pilot valve not lit

Turn off gas - allow unit to
vent for 5 minutes. Turn gas
back on and light pilot

Front or rear burner
won’t light

Control not on

Turn temperature control to ON
Set to desired setting when lit

Water in burner

Remove burner and dry
thoroughly

Damaged temperature control,
Burner or other internal
component

Contact Authorized Wells
Service Agency for repairs

Temperature control not set

Adjust for desired temperature

Shutter or nozzle out of
adjustment

Contact qualified technician for
adjustment

Damaged temperature control,
burner or other internal
component

Contact Authorized Wells
Service Agency for repairs

NOTE: There are no user
serviceable components in the
burner assemblies or in the con-
trol valves. In all cases of dam-
age or malfunction,
contact your Authorized Wells
Service Agency for repairs.

Burner not hot enough

Advertising