Base Grille Water Filtration System

Model WF-NLC120V Capacity 120 Gallons (454 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

Model WF-NLC120V: Change the water filter every
6 months. Use replacement cartridge NLC120V, part
#4396701. 2007 suggested retail price of $34.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.

Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI Standard 53 for the
reduction of Lead, Mercury, Benzene, p-dichlorobenzene, Cysts, Turbidity, Asbestos,
Endrin, O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene and against
NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class
I.

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Chlorine Taste/Odor
Particulate Class l

*

50%

85%

1.9 mg/L
5,300,000/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.12 mg/L
50,000/mL**

0.08 mg/L
15,725/mL

>75%
99.0%

>75%
99.7%

Contaminant
Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.01mg/L
0.01mg /L

0.14 mg/L

0.15 mg /L

0.15 mg/L ± 10%
0.15 mg /L ± 10%

0.001 mg/L
0.001 mg/L

0.001 mg/L
0.001 mg/L

99.29%
99.32%

99.29%
99.32%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.0055 mg/L

0.006 mg/L ± 10%
0.006 mg /L ± 10%

0.0005 mg/L
0.0013 mg /L

0.0003 mg/L
0.0005 mg/L

91.37%
76.36%

94.82%
90.90%

Benzene

0.005 mg/L

0.0153 mg/L

0.015 mg/L ± 10%

0.0036 mg/L

0.0014 mg/L

76.47%

90.84%

p-dichlorobenzene

0.075 mg/L

0.215 mg/L

0.225 mg/L ± 10%

0.0037 mg/L

0.0010 mg/L

98.27%

99.52%

Asbestos

99.0%**

842 x 10

7

10

7

to 10

8

fibers/L

††

1.6 x 10

7

mg/L

1.6 x 10

7

mg/L

99.81

99.81%

Cysts

Turbidity

99.95%
0.5 NTU

165,500/mL
11.75 NTU

50,000/L min.
11 ± 1 NTU

1 mg/L
0.38 NTU

1 mg/L
0.22 NTU

99.99%
96.76%

99.99%
98.12%

Endrin

0.002

0.0056

0.006 ± 10%

0.0007

0.0004

87.50

92.85

O-Dichlorobenzene

0.60

1.84

1.8 ± 10%

0.33

0.071

82.06

96.14

Toxaphene

0.003

0.0143

0.015 ± 10%

0.001

0.001

93.00

93.00

Ethyl Benzene

0.70

2.00

2.1 ± 10%

0.60

0.169

70.00

91.55

1,2,4- trichlorobenzene 0.07

0.232

0.21 ± 10%

0.0025

0.0007

98.92

99.69

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.89 L/min.) @ 60 psi

*

**

††

Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.