12

AUTOMATIC RE-IGNITION

If any one or more burners or grill
blow out, the electronic igniter
automatically activates to re-light
the flame.

Do not touch the burners

when the igniters are active.

IMPORTANT:

• For proper combustion do not

use the cooktop without the
burner grates in place.

• There is a slight sound

associated

with

gas

combustion and ignition. This is
a normal condition.

• On cooktops using propane

gas (LP), a slight “pop” sound
may be heard at the burner
ports a few seconds after the
burner has been turned off.

FLAME DESCRIPTION

• The burner flame color should

be blue with no yellow on the
tips. It is not uncommon to see
orange in the flame color; this
indicates the burning of
airborne impurities in the gas
and will disappear with use.

• With propane (LP) gas, slight

yellow tips on the primary cone
are normal.

• The flame should burn

completely around the burner
cap. If it doesn’t, check that the
cap is positioned correctly on
the base and that the ports are
not blocked.

• The flame should be stable with

no excessive noise or fluttering.

FLAME HEIGHT

• The correct flame height

depends on 1) size and
material of pan being used; 2)
food being cooked; and 3)
amount of liquid in the pan.

• Never extend the flame beyond

the base of the pan.

• Use a low or medium flame for

pan materials that conduct the
heat slowly, such as porcelain
coated steel or glass-ceramic.

POWER FAILURE

• In the event of a power failure,

only the standard burners can
be manually lit. It is necessary
to light each one individually.

• If the cooktop is being used

when the power failure occurs,
turn

all knobs to the OFF

position.

• The standard burners can be

lighted by holding a match at
the ports and turning the control
knob to the HI position. Wait
until the flame is burning all
around the burner cap before
adjusting the flame to the
desired height.

• Neither ExtraLow burner can be

used during a power failure.

Be

sure to turn them off.

• If either ExtraLow burner is on

when a power failure occurs,
they cannot be turned back on
until both knobs are first turned
off.

• The griddle or grill cannot be

used during a power failure.

• If you smell gas, refer to safety

precautions listed inside the
front cover.

Flame Color

S e c o n d a r y
Cone

Primary
Cone

Light Blue

Dark Blue

WARNING

In the event of a power failure,
all knobs are to be turned to the
OFF Position. Only the
standard burners can be lit
manually.

SECTION FOUR: USING THE COOKTOP

Warning

This product contains or,
through ordinary use for its
intended purpose, facilitates
emission of chemicals or other
substances known to the State
of California to cause cancer
and/or birth defects or other
reproductive harm. To mini-
mize exposure to these chemi-
cals:
1. The burners should be

adjusted by a certified
installer or agency to
ensure proper combustion.

2. Ensure proper ventilation

with an open window or
use a ventilation fan or
hood when cooking with
Gas.

3. Always operate the unit

according to the instruc-
tions in this manual.