Danger, 2 installing a thermostatic mixing valve – Rinnai E110CN FR Manuel d'utilisation

Page 28

Advertising
background image

Installation & Servicing Instructions Rinnai E-Series

28

6.5.2

Installing a Thermostatic Mixing Valve

A thermostatic mixing valve should be installed on all E combi boilers on the domestic
hot water side to prevent scalding. This valve will regulate the water temperature

leaving the brazed plate heat exchanger. See the figure 10 for the suggest piping.

DHW piping with thermostatic mixing valve

fig. 10

Hot water can be dangerous, especially for infants or children, the elderly,

or infirm. There is hot water scald potential if the thermostat is set too high.
Water temperatures over 125º F (51º C) can cause severe burns or

scalding resulting in death.
Hot water can cause first degree burns with exposure for as little as:
3 seconds at 140º F (60º C)
20 seconds at 130º F (54º C)
8 minutes at 120º F (48º C)
Test the temperature of the water before placing a child in the bath or

shower.
Do not leave a child or an infirm person in the bath unsupervised.