PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

Cleaner won’t start.

Poor job of dirt pick-up.

Cleaner starts but
cuts off.

Power Brush will not
run when attached.

Constant green light on
in dirt sensor.

Any, some, or all red
light in dirt sensor burn
and never turn green.

No green or red dirt
sensor lights.

Cleaner picks up move-
able rugs or Power
Brush pushes too hard.

Light won’t work.

Cleaner leaves marks
on carpet.

1. Unplugged at wall outlet.
2. Tripped circuit breaker/blown fuse at household

service panel.

3. Loose hose electrical connections.
4. Tripped overload protector in Power Brush

1. Full or clogged dust bag.
2. Clogged airflow passages.
3. Dirty Filters
4. Wrong pile height setting
5. Open suction control
6. Hole in hose
7. Worn Power Brush agitator
8. Worn or broken belt
9. Dirty agitator or end caps

1. Hose electrical connections.

2. Tripped overload protector in Power Brush.

3. Tripped overload protector in Power Unit.

1. Power Brush connections unplugged.

2. Worn or broken belt.

3. Dirty agitator or end caps.

4. Tripped overload protector in Power Brush

1. Dirt passage is clogged.
2. Lenses are dirty.

1. Dirt passage is clogged.

1. No power to sensor board.

1. Wrong pile height setting.
2. Suction too strong.

1. Burned out light bulb.

1. Wrong vacuuming pattern.

1. Plug in firmly, push ON/OFF switch to ON.
2. Reset circuit breaker or replace fuse.
3. Reconnect hose ends.
4. Clean agitator and end caps, then reset

(see page 9, 10, 11).

1. Change bag.
2. Clear airflow passages.
3. Change filters.
4. Adjust setting (page 7).
5. Adjust control (page 9).
6. Replace hose.
7. Change agitator (page 10).
8. and 9. See BELT CHANGING.

1. Check connections, reconnect hose ends.
2. Remove any items that may be caught or

jammed, then reset. If cleaner starts and stops
again, clean agitator and end caps, then reset
(page 9, 10, 11).

3. Change dust bag, clean airflow blockage.

Wait up to 50 minutes for motor to cool and
automatically reset.

1. Plug in firmly.
2. and 3. See BELT CHANGING AND AGITATOR.

CLEANING, (page 10).

4. Check agitator area for excessive lint build-up

or jamming. Clean agitator and end caps and
then reset.

1. Check for clogs in air passages (page 10).
2. Clean lenses (page 8).

1. Check for clogs in air passages (page 10).

1. Take to your nearest NuTone Service Center.

1. Adjust setting (page 7).
2. Open suction control (page 9).

1. Change light bulb (page 11).

1. See VACUUMING TIPS (page 7).

TROUBLESHOOTING

Review this chart to find do-it-yourself solutions for minor performance problems.
Any service needed, other than those described in this owner’s manual, should be
performed by an authorized service representative.

! WARNING

Electrical Shock Hazard

Disconnect electrical supply before servicing or cleaning the unit.
Failure to do so could result in electrical shock or personal injury.

!

13

Article

Pièce

Ampoule

9123A

Courroie

0518B

PIÈCES ET CARACTÉRISTIQUES

Vous devez bien connaître les pièces et les caractéristiques de votre aspirateur
pour être en mesure de l’utiliser de façon appropriée et sécuritaire. Examinez l’il-
lustration ci-dessous avant d’utiliser l’aspirateur.

Cordon et porte-

cordon

Poignée de

la rallonge

Porte-cordon

Cordon d’alimentation

Courroie

Ampoule et lentille

Indicateur de hauteur

de la brosse

Brosses latérales

(non illustrées)

Capteur de saleté

Pédale de réglage de la

hauteur des brosses

Pédale de dégage-

ment de la poignée

Numéro de

modèle/série

(sous l’appareil)

Pédale de dégagement

rapide du manche

4

Advertising