Mobile home installation, Venting, Outside air / floor securing – Napoleon Fireplaces 1600C-1 Manuel d'utilisation

Page 8

Advertising
background image

MOBILE HOME INSTALLATION

MODEL 1600C-1 IS APPROVED FOR INSTALLATION IN

MOBILE HOMES IN BOTH CANADA AND THE UNITED

STATES.

The stove must be secured to the floor of the mobile home.
Warning!

Do not install this stove in a bedroom/sleeping room.

Do not install the stove in any way that might

compromise the structural integrity of the mobile

home floor, walls, ceiling, or roof.

Venting

Connect the stove to a

chimney system using a

listed

double

wall

connector with a minimum

clearance rating of 12” or

less. Use chimney system

listed to ULC S629 in

Canada or UL103HT in the

USA.

The chimney must be

installed in accordance

with the manufacturer’s

instructions. Use only

specified components with

no substitutions. The

chimney and pipe

must

extend at least 8 feet

above the stove and 3 feet

above the highest point of

the roof. Install a rain cap at the top which will not impede

the smoke exhaust. The chimney must be supported at the

ceiling or roof so that its weight does not rest on the stove.

It must be installed between ceiling joists, with radiation

shield and roof flashing, so that the structural strength,

insulation and waterproof qualities of the home are not

lessened. Seal with silicone to maintain a vapour barrier at

the chimney and outside air pipe penetrations.

Outside air / Floor Securing

Connecting the stove’s air intake to the outside as well

as securing the unit to the floor, is mandatory in

mobile homes only. Use a fresh air kit and the floor

securing brackets.

Avoid cutting away floor joists, wall studs, electrical wires

or plumbing. Seal around the outside pipe with insulation

to prevent drafts.

If room air starvation occurs because the fresh air

intake is blocked with ice, leaves, etc., or because the

stove door was left open, or due to a strong exhaust

fan operating etc., dangerous fumes and smoke from

the operating stove could be drawn into the room.

113KT 1600C-1 Adaptor Kit Intallation

When installing the 1600C-1 in a mobile home,use the

111KT Outside air kit in conjunction with the 113KT

Outside Air Adaptor Kit.

Remove the two screws from the bottom of the unit and install

the two floor securing brackets using the two screws

removed.

Install the vent connector by inserting the stud retainer into

the hole in the bottom of the fireplace. Position the retainer so

that the studs come through the holes indicated.

Hold the retainer in place and align the holes in the vent

connector with the studs of the retainer.

Secure the vent connector in place using the 2 nuts supplied.

Secure the unit to the floor using the securing brackets and

the two #10x1.5" screws supplied.

8

C H A P E A U

S O L I N D E T O I T

P O U R M A I S O N M O B I L

É C R A N D E P R O T E C T I O

C E I L I N G S U P P O R T

T R I M C O L L A R

H E A R T H P A D

O U T S I D E A I R C O N N E C T I O N T H R O U G H

W A L L O R F L O O R

S T O V E B O L T E D

T O F L O O R

Advertising