Power unit installation, Tubing connections at power unit, Wiring – NuTone CV570 Manuel d'utilisation

Page 8: Dimensional chart, Figure 26 figure 27, Mounting, Figure 25 minimum wall clearance dimensions, 12" minimum to ceiling

Advertising
background image

8

1. Use black rubber connectors and hose clamps to connect intake

and exhaust tubing.

2. Connect intake tubing to intake tube on power unit.
3. Connect exhaust tubing to upper exhaust tube on power unit.
4. Make sure all tubing connections are securely fastened.
5. An optional muffler (Model 392) may be installed to reduce

motor noise.

6. The exhaust should not be vented into a wall, ceiling or concealed

space in the house. Exterior vented exhaust lines should be term-
inated using Model 393 Wall Caps or appropriate louvered
exhaust vents.

POWER UNIT INSTALLATION

FIGURE 26

FIGURE 27

TUBING CONNECTIONS AT POWER UNIT

MOUNTING

See Figure 25. Also refer to page 3.

1. Locate power unit within six feet of a grounded electrical outlet.
2. Remove mounting bracket from power unit and attach to wall,

following minimum clearances noted in Figure 25. Screws must be
secured into a wall stud or other suitable support.

3. Hang power unit securely on bracket.

WIRING

See Figure 27.

Grounding Instructions – This appliance must be grounded. If it

should malfunction or break down, grounding provides a path of least
resistance for electric current, to reduce the risk of electric shock. This
appliance is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.

Danger –

Improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as to whether the outlet
is properly grounded. Do not modify the plug provided with the
appliance – if it will not fit the outlet, have a proper outlet installed by a
qualified electrician.

This appliance is for use on a nominal 120 volt circuit and has a

grounding plug. Make sure that the appliance is connected to an outlet
having the same configuration as the plug. No adapter should be used
with this appliance.
1. Connect low voltage wire (18 gauge, 2-conductor, Model 376-UL or

376) to crimp connectors located on outside of the power unit.

2. The power unit is equipped with a six foot grounded cord.

Plug cord into 120 volt grounded receptacle.

CONVENIENCE

OUTLET

MOUNTING

BRACKET

INLET

INLET

INLET

TO

OTHER
INLETS

POWER

UNIT

DIMENSIONAL CHART

DIMENSION

CV554

CV556

CV570

A

11

3

4

"

11

3

4

"

15

1

8

"

B

40

3

8

"

41

1

4

"

39"

C

4

3

4

"

6"

4

3

8

"

D

2

3

8

"

2

1

2

"

5"

E

17

7

8

"

18

1

2

"

20

1

2

"

F

15

1

2

"

15

1

2

"

15

1

2

"

FIGURE 25

MINIMUM WALL CLEARANCE DIMENSIONS

18"

18"

BACK VIEW

C

D

F

INTAKE

EXHAUST

CONVENIENCE

OUTLET

12" MINIMUM TO CEILING

FRONT VIEW

C

E

B

OVERALL

HEIGHT

INTAKE

18" MINIMUM ABOVE FLOOR

(MORE IS RECOMMENDED)

A

TOP VIEW

WIRING

MODEL

376-UL

OR

376

(18

1

2

) WIRE

POWER

CORD

120 VAC

ELECTRICAL

OUTLET

PUSH-ON

CONNECTORS

®

NOTE: INLET

LEADS CONNECT

TO POWER UNIT

USING PUSH-ON

CONNECTORS

SUPPLIED ON

POWER UNIT

Advertising