FLOOR INLET INSTALLATION

FLOOR

SUB-FLOOR

2

9

/

16

"

3

1

/

16

"

INLET

EXTENSION

FLOOR

INLET

FRAME

MOUNTING

BRACKET

SEAL

FLANGED

FITTING

FIGURE 40

CUT TO

LENGTH

EXTENSION

SLEEVE

FLANGED

FITTING

MOUNTING

BRACKET

FLANGE

FIGURE 41

WALL
INLET

EXTENSION SLEEVE

BRACKET

FLANGED FITTING

TUBING

FIGURE 42

FINAL SYSTEM CHECK

Be sure all inlets are closed and lower cannister is in place.

Check switch on power unit for manual on/off operation.

Check each wall inlet to be sure contacts activate power unit

when hose is inserted and switched on, if applicable. If Central
Cleaning hose is not available at the time, a short piece of wire
can be used to short contacts in wall inlet to activate power unit.
Check each wall inlet and tubing connection for air leaks. Check
power unit for leaks around inlet tube and dirt cannister.

Make sure the permanent cloth filter is properly installed in the

power unit according to directions in the homeowner’s operating
instructions.

Now it’s time to enjoy the benefits of a NuTone Central Cleaning
System.