Wiring diagrams, Reinstall bottom vent, Complete installation – KITCHENAID 9760618 Manuel d'utilisation

Page 12

Advertising
background image

12

If oven does not operate:

Check that power supply is turned on.

Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.

Repeat start-up. If the oven still does not operate at this point,
contact your dealer or authorized service company for
assistance.

Install Burner Grates

Place burner grates over burner caps. The simmer plate may sit
on one of the grates or be stored for future use.

Reinstall Bottom Vent

1. Insert lower vent tabs into the slots on the front trim.

2. Push vent upward until the holes line up at top of vent.

3. Reattach the vent using the 4 screws.

Complete Installation

1. Check that all parts are now installed. If there is an extra part,

go back through the steps to see which step was skipped.

2. Check that range is correctly positioned in countertop cutout

and that the range is level. See “Level Range.”

3. Check that the specified distances to cabinet surfaces were

maintained. See “Location Requirements.”

4. Check that burner caps are positioned properly on sealed

burner bases.

5. Check that backguard or island trim is installed. (If horizontal

clearance to combustible materials behind cooking surface is
less than 1" [2.5 cm]).

6. Check that the range is connected only to the type of gas for

which it is certified for use.

7. Use a mild solution of liquid household cleaner and warm

water to remove waxy residue caused by protective shipping
material. Dry thoroughly with a soft cloth. For more
information, see the “Range Care” section of the Use and
Care Guide.

8. Read “Range Use” in the Use and Care Guide.

9. Turn on surface burners and oven. See the Use and Care

Guide for specific instruction on range operation.

If range does not operate, check the following:

Household fuse has not blown, or circuit breaker has not
tripped.

Gas valves are turned to the “ON” position.

If the gas supply line shutoff valve is open, contact a qualified
technician.

Electrical supply is connected.

See “Troubleshooting” in the Use and Care Guide.

WIRING DIAGRAMS

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Cooktop Schematic

A. Bottom vent
B. Reattach these screws.

A

B

L1

L2

N

VALVE SWITCHES

IGNITER ELECT RODES

SPARK
MODULE

Y OR BR (6) PLCS

W

R

W

W

W

W

GR

R

GND

Advertising