John Deere AC1-5E Manuel d'utilisation

Page 16

Advertising
background image

6

Hand Carry Electric Air Compressor Manual

Move unit to a well ventilated area.

Repair or replace gaskets and

valves. Torque head bolts to 7ft./lbs.

Replace thermal overload.

Contact motor repair center if still

having problems.

The motor thermal overload contin-

ues to trip or fails to reset.

Improper ventilation causing the

pump or motor to overheat.

Defective head gasket or faulty

(reed) valve.

Faulty motor thermal overload.

Air compressor starts but does not

build up pressure.

Tighten connection.

Air bleed off line is loose.

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY

Air tank drain valve is open.

Air leaks at connections.

Completely close air tank drain

valve.

Allow the air compressor to build

pressure to the maximum allowed.

Turn off and brush a soapy wa-

ter solution onto all connections.

Check connections for air bubbles.

Tighten the connections where

leaks are present.

Air leak in air tank.

Air tank must be replaced.

Do not attempt to repair

air tank!

Defective check valve.

Remove, clean or replace.

Pressure loss in system.

Lack of oil in the pump.

Carbon deposits on pistons or

valves.

Bearing, piston or connecting rod

failure.

Add correct amount of oil. Check for

bearing damage.

Remove cylinder head and inspect.

Clean or replace valve plate.

STOP THE AIR COMPRESSOR!

Contact your Customer Service.

Noisy operation.

Pressure switch does not shut off

motor when air compressor reaches

"Stop" pressure and safety relief

valve activates.

Air compressor is not large enough

for air required.

Motor runs continuously.

Push the pressure switch lever to

the "OFF" position. If the motor

does not shut off, unplug the air

compressor. If the electrical con-

tacts are welded together, replace

the pressure switch.

Check the accessory air require-

ment. If it is higher than the CFM or

pressure supply of the air compres-

sor, you need a larger air compres-

sor.

Advertising