Warning, Complete installation – Maytag W10160251A Manuel d'utilisation

Page 16

Advertising
background image

16

6. Hang door by placing screw heads into top slotted holes of hinges and slide door down.

Align bottom screw holes in hinge and door. Install two bottom screws. Tighten all hinge
screws.

7. Close door to engage door strike.

Complete Installation

1. Check that all parts are now installed. If there is an extra part, go back through the steps to

see which step was skipped.

2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Be sure the water faucets are on.
5. Check for leaks around “Y” connector, faucet and hoses.
6. Check the dryer’s final location. Be sure the vent is not crushed or kinked.

7. Check that the dryer is level. See “Level Dryer.”

8. Plug into a grounded 3 prong outlet. Turn on power.
9. Remove any protective film or tape remaining on the dryer.

NOTE: Glass door models have a protective film on the window that should be removed.

10. Read “Dryer Use.”
11. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
12. If you live in a hard water area, use of a water softener is recommended to control the

buildup of scale through the water system in the dryer. Over time, the buildup of lime
scale may clog different parts of the water system, which will reduce product
performance. Excessive scale buildup may lead to the need for certain part replacement
or repair.

13. Test dryer operation by selecting a Timed Dry heated cycle and starting the dryer. For this

test, do not select the Air Fluff modifier.
If the dryer will not start, check the following:

Dryer is plugged into a grounded 3 prong outlet.

Electrical supply is connected.

Household fuse is intact and tight, or circuit breaker has not tripped.

Dryer door is closed.

14. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If

you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and
check that the gas supply line shutoff valve is open.

If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as
outlined above.

If the gas supply line shutoff valve is open, contact a qualified technician.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Advertising