5

IR

S

ENSOR

A

CTIVATION


An infrared (IR) sensor located behind the scanner window initiates the scanning
process. In short range mode the signal projects approximately 101.61 mm –
177.84 mm (4" – 7") beyond the output window. In long range mode the signal
projects approximately 228.61 mm – 330.21 mm (9" – 13") beyond the output
window. The IR sensor remains active as long as the unit is powered.

When the unit remains dormant for a time, the laser will turn off. In this stage, the
scan engine’s computer is on “standby”. To reactivate the unit, present an object
within the scan field.




A

PPLICATIONS AND

P

ROTOCOLS

The model number on each scan engine includes the scan engine number and
communications protocol.

Unit

Communication Protocol(s)

Type

IS4110 Laser

Data

Non-decode

IS4125-41

RS232 and Light Pen Emulation

(Flash Upgradeable Firmware)

IS4125-17

Keyboard Wedge, Stand Alone Keyboard

(Flash Upgradeable Firmware)

IS4125-38

Low Speed USB

Keyboard Emulation or Serial Emulation Mode

IS4125-103 TTL,

RS232

Decode