IS4125-103 Connector Pin Assignments

Metrologic provides a low profile ZIF 12-pin
connector to connect to a 1 mm x 12 position
FFC/FPC cable. The pin assignments are as follows:

Pin

Signal

Name

Function

1 VCC

Input. 5VDC (± 0.25V)
This requires 25 mA in standby and 130 mA peak.

2

Ground

Signal and power ground.

3 Receive

Input. RS232 receive data from host.
Nominal ±12V signals.

4

TTL Receive

Input. +5/0V

5 RTS

Output, RS232 Ready to send signal from the scan engine.
Nominal ±12V signals.

6 TTL

Transmit

Output.

+5/0V

7 Transmit

Output. RS232 transmit data from the scan engine.
Nominal ±12V signals.

8 CTS

Input. RS232 clear to send signal from host.
Nominal ±12V signals.

9*

Good Read

Indicator

Output. 5V high with a 2 kHz pulse. This drain is the pin of
a PFET type transistor that can source approximately
100 mA of current. This output is the connection for an
LED or other indicator (i.e. beeper+). It is recommended
that the indicator is terminated directly to ground.

10* Beeper

-

Input. Collector of an NPN transistor that can sink
approximately 100 mA of current. A current limiting pull-up
resistor and Piezo type transducer (QMB- 111PXN or
equivalent) is recommended.

11 Reserved

Input

Input. Do not connect to this pin. This pin is for Metrologic
internal use only.

12 LED

-

Negative connection for LED. An external pull-up and LED
are suggested. Maximum current is limited to 25 mA.
This line is active low when the laser diode is active.

* Pins 9 and 10 can be used together to form a push-pull type circuit. Pin 9

becomes the Beeper + and Good - Read source whereas Pin 10 supplies the
pathway to ground.