gaC6HZR 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 23

OperatiOn/sHutdOwn

12. Read voltmeter on front panel of generator (Figure 20)

and verify that 240 VAC is displayed. Using an external

voltmeter as shown in Figure 20, verify that 240 VAC

is present at the 240V twist-lock receptacle.

Figure 20. 240V Receptacle

13. Connecting of loads (power tools, lighting ect.) to the

generator receptacles can now be done.

stopping the engine (Normal shutdown)

1. Place main circuit breaker (Figure 21) in the

OFF

position.

Figure 21. Main Circuit Breaker (OFF)

NOTICE

When using a combination of dual receptacles, total

load should not exceed the rated capacity of the

generator.

2. Place GFCI circuit breaker (Figure 22) in the

OFF

positing.

Figure 22. GFCI Circuit Breaker (OFF)

3. Place idle control switch (Figure 23) in the

OFF position.

Figure 23. Idle Control switch (OFF)

4. Let engine run at idle with no load for 2-3 minutes.
5. To shut-down the engine, place the generator's

operation switch (Figure 24) in the

OFF position).

Figure 24. Operation Switch (OFF)

6. Place engine fuel valve lever (Figure 25) in the

OFF

position.

Figure 25. Engine Fuel Valve Lever (OFF)

7. Remove all loads from the generator.

emergency shutdown

8. Place operation switch (Figure 24) in the

OFF position