OperatiOn

6. If the engine has started, slowly return the choke lever

(Figure 12) to the

OpeN position. If the engine has not

started repeat steps 1 through 5.

7. Before the generator is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells,

fuel leaks, and noises that would associate with lose

components.

8. Place idle control switch (Figure 15) in the

OFF (down)

position. This will allow the engine speed to run at about

3600 RPM's.

Figure 15. Idle Control Switch (OFF)

Figure 16. Idle Control switch (ON)

NOTICE

Placing the idle control switch in the

OFF position

(Figure 15) allows the engine to operate at a maximum

speed of about 3600 RPM's.
When the idle control switch (Figure 16) is placed in the

up position (

ON), the generator will run at idle speed

(2200 RPM's) until a load is applied, at that time the

engine speed will increase to 3600 RPM's as long as

a load is being applied.
When the load is not in use, the engine speed will drop

back to the idle mode after about 3 seconds.

9. Place main circuit breaker (Figure 19) in the

ON

position.

Figure 17. Main Circuit Breaker (ON)

10. Place GFCI circuit breaker (Figure 19) in the

ON

position.

Figure 18. GFCI Circuit Breaker (ON)

11. Read voltmeter on front panel of generator (Figure 19)

and verify that 120 VAC is displayed. Using an external

voltmeter as shown in Figure 19, verify that 120 VAC

is present at the 120V twist-lock and GFCI duplex

receptacles. .

Figure 19. 120V/GFCI Receptacles