Gas conversions, Warning, Lp gas conversion – Maytag W10258096A Manuel d'utilisation

Page 13

Advertising
background image

13

GAS CONVERSIONS

Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.

LP Gas Conversion

1. Turn manual shutoff valve to the closed position.

2. Unplug range or disconnect power.

To Convert Gas Pressure Regulator

1. Remove oven racks from inside the oven cavity.

2. Remove the storage drawer. See “Replace Oven Racks and

Storage Drawer” section.

3. Remove the oven door. See “Oven Door” section in the Use

and Care Guide for oven door removal instructions.

4. Using a Phillips screwdriver, remove and set aside the 2 oven

bake burner cover screws located at the rear of the oven.

5. Lift up and remove oven bake burner cover.

6. Remove the 3 bake burner screws and set aside.

7. Swing the bake burner to the side and lift it off the oven

orifice and set aside.

8. Locate gas pressure regulator at the rear of the range.

IMPORTANT: Do not remove the gas pressure regulator.

A. To range
B. Shutoff valve (closed position)

C. Gas supply line

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.

Examples of a qualified person include:

licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death
or serious burns to children and adults.

A

B

C

A. Bake burner cover
B. Bake burner cover screws

A. Oven orifice
B. Bake burner screws

A

B

A

B

B

2

Advertising