Chapter iii heater operating instructions – Mr. Heater GAS FIRED INFRA-RED WORKSHOP HEATER MH25LP / MH25NG Manuel d'utilisation

Page 10

Advertising
background image

MANUAL GAS

CONTROL KNOB

PILOTSTAT

POWER UNIT

PRESSURE
REGULATOR
ADJUSTMENT

STANDARD
PRESSURE
REGULATOR

PILOT GAS OUTLET
(PRESSURE TAPPING
DIRECTLY BENEATH)

PILOT FLOW ADJUSTING SCREW
(BENEATH COVER SCREW)

WRENCH

BOSS

GAS

INLET

Figure 9. Gas Valve Components

2. HEATER STARTUP

WARNING: During heater startup ensure that

building is well ventilated.

A. Open the gas supply valve or valves.
B. Set the thermostat to the OFF position.

See Figure 8.

C. If the manual gas control knob on the gas valve is

not in the OFF position, partially depress the knob
and rotate to the OFF position. See Figure 9.

CHAPTER III

HEATER OPERATING

INSTRUCTIONS

1. OPERATING SAFETY INSTRUCTIONS

WARNING: When used without fresh air, heater may

give off CARBON MONOXIDE, an odorless poison-

ous gas. OPEN WINDOW AN INCH OR TWO FOR

FRESH AIR WHEN USING HEATER.

WARNING: This heater is equipped with a PILOT

LIGHT SAFETY SYSTEM. DO NOT TAMPER WITH

PILOT LIGHT SAFETY SYSTEM.

WARNING: If heater shuts off, do not relight until you

provide fresh air. Open door for 5 minutes. If heater

keeps shutting off, have it serviced. Keep burner and

control clean.

WARNING: CARBON MONOXIDE POISONING MAY

LEAD TO DEATH. Early signs of carbon monoxide

poisoning resemble the flu with headache, dizziness

and/or nausea. If you have these signs, heater may

not be working properly. Get fresh air at once! Have

heater serviced.

WARNING: DO NOT USE MATCH OR OTHER

FLAME FOR LEAK TESTING.

CAUTION: If the infra-red color of the grid becomes

dull when the building furnace is operating, consult

gas supplier on correct gas supply piping sizes.
CAUTION: This heater is for indoor installation only!

NOTE

Gasket binder material used in this heater assembly

will temporarily emit an odor and/or vapor. This condi-

tion will clear up in approximately 20 minutes and

thereafter will not reoccur. Refer to Chapter 2 for

ventilation.

FIGURE 8. THERMOSTAT CONTROLS

10

Installation instructions and Owner’s Manual

Model # MH25NG/LP

HS25NG/LP

Advertising