ERROR LOGIC & TROUBLESHOOTING continued

Motor Error2

Occurs when the platen is in motion

and fails to reach the upper or lower

limit position within 30 seconds,

(150 encoder counts)

Recycle Main

Power Switch

Audio Alarm

L1: MOTOR
L2: ERROR2

Lower Switch Error

Occurs at cycle start when the

lower limit switch fails to signal the

platen’s arrival at the lower limit

position within 200 seconds.

Recycle Main

Power Switch

Audio Alarm

L1: LOWER SWITCH
L2: FAIL

Upper Switch Error

Appears in code,

but is never set.

Recycle Main

Power Switch

Audio Alarm

L1: UPPER SWITCH
L2: FAIL