Faber 280 CFM Manuel d'utilisation

Page 6

Advertising
background image

Version 03/08- Page 6

1” min

16

3/8”

max

22”

9

1/2”

36”

x

also consult cooktop

manufacturer's recommendation

upper

chimney

lower

chimney

canopy

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

cabinet base

FIGURE 4

19

1/4”

PREPARE THE WALL

1. Disconnect and move freestanding range from cabinet

opening to provide easier access to upper cabinet and rear

wall. Put a thick, protective covering over cooktop, set-in

range or countertop to protect from damage or dirt.

2. Determine and clearly mark with a pencil the center line

on the wall where the rangehood will be installed.

3. The canopy attaches to the wall by two mounting brackets

(1 in FIGURE 5). The canopy of the rangehood hangs on

the two brackets which must be mounted with the flanges

on the top of the bracket and pointing away from the wall.

Before installing the brackets, the adjustment screws must

be installed into the bottom of the bracket. These two

screws are provided in the hardware package and have

hexagon heads with a slot for a flat blade screwdriver.

The dimensions illustrate mounting the canopy 24" above

the cooking surface.

If a Backsplash is to be used with this rangehood, it must

be installed before the rangehood. Installation instructions

for the Backsplash are supplied in its box. The height

of the Backsplash will determine the bottom edge of

the canopy.

4. The chimney mounts by two brackets (2 in FIGURE 5).

Note the position of the brackets. The top bracket should

be installed about 1/8" away from the ceiling. The bottom

bracket must be installed at the bottom point of the upper

chimney sleeve.

Determine the proper location for each bracket and install

the brackets on the wall. MAKE SURE THAT THE BRACK-

ETS ARE SECURELY FASTENED TO THE WALL.

5. Determine and make all necessary cuts in the wall for the

ductwork. Install the ductwork before the rangehood.

6. Determine the proper location for the Power Supply

Cable (FIGURE 6). Use a 1 1/4" Drill Bit to make this

hole. Run the Power Supply Cable. Use caulking to seal

around the hole. DO NOT turn on the power until instal-

lation is complete.

INSTALLATION DIMENSIONS

The Synthesis chimneys are adjustable and designed to meet varying ceiling

heights as indicated in FIGURE 4. The chimneys can be adjusted for ceil-

ings between 7' 8 1/2" and 9' 5 7/8" depending on the distance between

the bottom of the hood and the cooktop (distance x in FIGURE 4).

FIGURE 5

FIGURE 6

30 MODELS

36 MODELS

For shorter ceilings,

have the chimney

cover(s) cut at a sheet

metal shop. For higher

ceiling installations, the

High Ceiling Chimney

Kit includes a new 40”

upper chimney which

would replace the 16

3/8” upper chimney that

came with the hood.

min & max ceiling height examples

x = 30"

min

8'

2 1/2"

max

9'

5 7/8"

x = 28"

min

8'

1/2"

max

9'

3 7/8"

x = 26"

min

7'

10 1/2"

max

9'

1 7/8"

x = 24"

min

7'

8 1/2"

max

8'

11 7/8"