TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

• 1 Hardware Package

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap

Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 3

3.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 2

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 35 equivalent feet

if ducted with the required minimum of 6" round

ductwork. Calculate the length of the ductwork

by adding the equivalent feet in FIGURE 2 for

each piece of duct in the system An example

is given in FIGURE 3.

For best results, use no more than three 90°

elbows. Make sure that there is a minimum of

24" of straight duct between elbows if more

than one is used. Do not install two elbows

together. If you must elbow right away, do it

as far away from the hood's exhaust opening

as possible.

WARNING

Because of the weight and size of the

rangehood canopy, two or more people

are needed to move and safely install the

rangehood canopy.

Failure to properly lift rangehood could

result in damage to the product or personal

injury.

PERSONAL INJURY HAZARD

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or ductless. In a ducted

application, this rangehood can be vented through the wall or ceiling. To vent

through a wall, a 90° elbow is used. When installed ductless, the rangehood

vents out of grates on the sides of the chimney. Ductless installations require

a Ductless Conversion Kit, available from your dealer.

WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,

DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY

CALCULATE ALL MEASUREMENTS.

RANGEHOOD COMPONENTS

FIGURE 1

A. CANOPY SECTION

B. LOWER CHIMNEY COVER

C. UPPER CHIMNEY COVER

D. CANOPY MOUNTING BRACKETS

E. CANOPY MOUNTING BRACKET

F. MOUNTING SCREWS

G. CHIMNEY MOUNTING BRACKETS

H. DAMPER

I. CHIMNEY SCREWS

ADJUSTMENT SCREWS

!

G

I

H