FIGURE 9

6. Connect the Power Supply Cable to the rangehood. At-

tach the White lead of the power supply to the White lead of

the rangehood with a twist-on type wire connector. Attach

the Black lead of the power supply to the Black lead of the

rangehood with a twist-on type wire connector. Connect

the Green (Green and Yellow) ground wire under the Green

grounding screw.

7. Replace the field wiring compartment cover and the grease

filters

8. For ducted installations, the damper must be attached to

the exhaust opening on the top of the canopy. Connect the

ductwork and seal all connections with duct tape.

FOR DUCTLESS INSTALLATIONS

Do not use the damper for ductless installations. The UPPER

CHIMNEY COVER must be installed first, before the LOWER

CHIMNEY DUCTLESS.

Ductless installations require a Ductless Conversion Kit.

This kit consists of a LOWER CHIMNEY DUCTLESS (A in

FIGURE 10) with holes for the exhaust air, a DUCTLESS

DIVERTER (C), two VENT GRIDS (B) to cover the holes in

the chimney cover, and two CHARCOAL FILTERS (D). The

DUCTLESS DIVERTER must be installed before the LOWER

CHIMNEY DUCTLESS is attached (as indicated by the arrow

in FIGURE 10). The LOWER CHIMNEY COVER without

holes should be discarded.

Once the LOWER CHIMNEY DUCTLESS with holes is

installed, the VENT GRIDS (B) are inserted into the holes

(FIGURE 11).

Attach the CHARCOAL FILTERS to both sides of the blower

(as indicated in FIGURE 12). Install the grease filters.

FIGURE 10

5. Level the canopy.

The height and level

of the canopy can be

adjusted by rotating

the adjustment screws

(Item R in FIGURE

9) on each side of

the blower inside the

rangehood

FIGURE 11

FIGURE 12

9. The chimney must be attached to the body of the rangehood,

as indicated in FIGURE 13. The UPPER CHIMNEY COVER

(C) must be installed first, then the LOWER CHIMNEY

COVER (B) wraps around it. Both sections are secured to

the wall under the CHIMNEY MOUNTING BRACKETS (H).

Secure the UPPER CHIMNEY COVER to the MOUNTING

BRACKETS with the CHIMNEY SCREWS (J). Secure the

LOWER CHIMNEY COVER to the CANOPY (A) by inserting

the flanges at the bottom of the LOWER CHIMNEY COVER

into the holes on the CANOPY.

10. Turn the power supply on. Turn on blower and light. If

the rangehood does not operate, check that the circuit breaker

is not tripped or the house fuse blown. If the unit still does

not operate, disconnect the power supply and check that the

wiring connections have been made properly.