TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

• 1 Hardware Package

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork

FIGURE 1

WARNING

Because of the weight and size of the rangehood canopy, two or

more people are needed to move and safely install the rangehood

canopy. Failure to properly lift rangehood could result in damage

to the product or personal injury.

PERSONAL INJURY HAZARD

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or

ductless. In a ducted application, this rangehood can

be vented through the wall or ceiling. To vent through

a wall, a 90° elbow is used. When installed ductless,

the rangehood vents out of grates on the sides of the

chimney. Ductless installations require a Ductless

Conversion Kit, available from your dealer.

WARNING! BEFORE MAKING ANY CUTS OR

HOLES FOR INSTALLATION, DETERMINE WHICH

VENTING METHOD WILL BE USED AND CAREFULLY

CALCULATE ALL MEASUREMENTS.

RANGEHOOD ASSEMBLY

PLAN THE INSTALLATION

The Perla chimneys are adjustable and designed to meet varying ceiling

heights as indicated in FIGURE 2. The chimneys can be adjusted for ceil-

ings between 7' 8 1/2" and 9' 9 1/2" depending on the distance between

the bottom of the hood and the cooktop (distance x in FIGURE 2).

For shorter ceilings, have the chimney cover(s) cut at a sheet metal shop.

For higher ceiling installations, the High Ceiling Chimney Kit includes a

new 40” upper chimney which would replace the 20” upper chimney that

came with the hood. (see OPTIONAL ACCESSORIES page 4)

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap

Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 4

3.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 3

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 35 equivalent

feet if ducted with the required minimum of

6" round ductwork. Calculate the length of

the ductwork by adding the equivalent feet in

FIGURE 3 for each piece of duct in the system.

An example is given in FIGURE 4.

For best results, use no more than three

90° elbows. Make sure that there is a

minimum of 24" of straight duct between

elbows if more than one is used. Do not

install two elbows together. If you must

elbow right away, do it as far away from the

hood's exhaust opening as possible.

1” min

20” max

22”

9

1/2”

36”

x

also consult cooktop

manufacturer's recommendation

upper

chimney

lower

chimney

canopy

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

cabinet base

FIGURE 2

19

3/8”

min & max ceiling height examples

x = 30"

min

8'

2 1/2"

max

9'

9 1/2"

x = 28"

min

8'

1/2"

max

9'

7 1/2"

x = 26"

min

7'

10 1/2"

max

9'

5 1/2"

x = 24"

min

7'

8 1/2"

max

9'

3 1/2"

!