TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape
PARTS SUPPLIED FOR INSTALLATION

• 1 Backdraft Damper

• 1 Literature Package
PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE

• Charcoal Filters

For non-vented installations only,

replace charcoal filters as needed

part # FILTER1

PLAN THE DUCTWORK

The Velvet slideout rangehood is designed to offer wide flexibility of installations.

The rangehood can be ducted through a 6" round vent. The unit can also be

installed in a recirculating configuration. The unit comes standard in the top

venting position. FIGURE 3 shows recirculating installation.

The Velvet requires 6" round ductwork. To ensure that the blower performs to

its highest possible capacity, ductwork should be as short and straight as pos-

silbe.

RECIRCULATING INSTALLATIONS

For recirculating installations (FIGURE 3), Charcoal Filters are necessary. Open the comfort panel by turning the knobs to the

right, slide open the glass visor, and remove the grease filters and set aside. Attach one charcoal filter to each end of the blower.

Each charcoal filter attaches to the of the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove

(FIGURE 3A). Replace the grease filters and reattach the comfort panel. Some ductwork must be installed to exhaust the

rangehood back into the kitchen, either at the top of the cabinet or at the face of the soffit. Using a plastic vent grate to cover

the duct opening.

This duct work must not terminate into a dead air space

.

FIGURE 3A

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE A

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

FIGURE B

3.0 feet

5.0 feet

12.0 feet

0.0 feet

cabinet

ceiling

6” round

duct

hood

cabinet

ceiling

6” round

duct

hood

soffit

vent grate

vent grate

FIGURE 3

The ductrun should not exceed 35 feet if ducted

with the required minimum of 6" round duct. Cal-

culate the length of the ductwork by adding the

equivalent feet in FIGURE A for each piece of duct

in the system An example is given in FIGURE B.

For best results, use no more than three 90°

elbows. Make sure that there is a minimum of

24" of straight duct between elbows if more

than one is used. Do not install two elbows

together. If you must elbow right away, do it

as far away from the hood's exhaust opening

as possible.

VERTICAL

DUCTING

FIGURE 2

HORIZONTAL

DUCTING

FIGURE 1

For direct rear venting (FIGURE 2), you

must change the blower position. Remove

the 12 screws that hold the metal housing

to the rangehood body. Rotate the blower

90 degrees toward the back and then flip it

over 180 degrees. Be sure that the power

supply cable is properly positioned. Replace

all screws, making sure that they are firmly

fastened.