Problem: Red Caution Light Lit, Loss of Suction or Overheating
of the Motor

Problem: Machine will not operate

13

ENGLISH

Do It Yourself Service Chart

Clogged Flat Disc Filter

Replace Flat Disc Filter.

Obstructed Hose

See instructions (6) under
“Power Nozzle Does Not Operate.”

Obstructed Wand

Run long wire or a straightened
coat hanger through wand.

Obstruction at neck of
Power Nozzle

See instruction (4) under “Power
Nozzle Does Not Operate”

Filter Cone coated with
extremely fine dust

Empty Dirt Container and
replace Filter Cone. Flat Disc
Filter may also need to be replaced.

Plug not connected to
outlet, or a faulty one

Insert plug firmly into wall outlet or
try another outlet.

Motor overheated and
tripped automatic shut-off

Turn power switch to “O” off and
unplug power cord from wall. Let
unit cool. Check for blockage in
attachment. Filter cones may also
need to be replaced.

Damaged switch

Call your local FILTERQUEEN

®

Distributor

for service.

Damaged motor

Call your local FILTERQUEEN

®

Distributor

for service.

Damaged power cord plug

Call your local FILTERQUEEN

®

Distributor

for service.

Cause:

Correction:

Cause:

Correction: