A. Changing The Filter Cones

For best performance, replace Cones as recommended by manufacturer:

▼ Pre-Filter - every month
▼ MEDIpure

®

- every 6 months

▼ Flat Disc Filter - every 6 months

CAUTION -

DO NOT operate your power unit without Genuine FILTERQUEEN

®

Filter Cones in place.

BEWARE OF IMITATIONS:

Use only Genuine FILTERQUEEN

®

Filter Cones. Imitations can result

in poor performance and cause damage to your unit.
1. Unplug power cord from wall and detach hose from power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove MEDIpure

®

Cone and set aside or discard when installing a new

Pre-Filter.

4. Empty contents of dirt container into a large, open garbage bag. Allow contents of

container to fall including used Pre-Filter Cone. Dirt container may be
washed and thoroughly dried to remove all dust and/or any odors.

5. Open a new Pre-Filter Cone. Insert point of Cone into Filter Cone locator

in the bottom of the dirt container. Be sure all edges of the Cone are even with the
gasket of the dirt container.

6. Place the MEDIPure

®

Cone inside the Pre-Filter.

7. Replace power unit and lock side clamps in place. Be sure all three tabs of the

Pre-Filter Cone are visible outside the power unit.

B. Changing The Flat Disc Filter

1. Unplug power cord from wall and detach hose power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove the Cone guard. Next, remove the Flat Disc Filter by pulling back the

plastic retainer ring with your finger and lifting it out.

4. Replace Flat Disc Filter. Place the filter over the center section of the screen. Replace

the retainer ring by squeezing ring. Make sure ring fits snugly under the three tabs
of the plastic screen. Replace the Cone guard. Be sure the outer edge of the Cone is
seated on the rubber lip around the circumference of the power unit and replace screw.