Frymaster SDU Manuel d'utilisation

Pump handle, Spout locking pin, Tank

Advertising
background image

Pump Handle

Turn clockwise to

dispose of oil.

Spout Locking Pin

Release to pivot spout

toward disposal vessel.

Tank

Do not fi ll above

marked fi ll line; do

not move without the

lid securely clasped.

Crumb Tray

Ensure the crumb

tray is present and

clean.

Do clean crumb

tray and inside

tank.

Do prime pump

after long periods

of non use.

Don’t fi ll with

water or use to

drain boilout solu-

tion.

Don’t move with-

out the handle

bolts or locking

pins in place.

Don’t use

without the

crumb tray.

Don’t overfi ll.

Don’t move with

the lid unlatched.

Don’t leave oil in

the tank.

DO’S

DON’TS

USING AN SDU

• Place the open tank under

the drain valve or drain ex-

tension of a fryer. Ensure the

fryer is off and the oil is no

more than 100°F.

• Slowly open the drain

valve. Fill only to the fi ll line

on the tank. Drain only one

vat at a time.

• Close and secure the lid of

the SDU. Roll it to the dis-

posal site. Rotate the pump’s

spout as necessary to reach

the disposal vessel.

• Turn the crank clockwise to

dispose of the oil.

• The pump may require

priming: Lift the pump as-

sembly from the tank and

turn upside down. Pour one

cup of cooking oil into the

pipe. With the pump still in-

verted, turn the handle slowly

clockwise two to three times.

Return the pump to the tank.

Handle Bolts

(or locking pins)

Ensure bolts or locking pins

are in place before moving

the SDU.

819-6210

06/06

These instructions are intended as a quick reference. Read the manual which ac-

companied this product and follow all safety guidelines.

Advertising