En 9 9 – Franke Consumer Products FMY 367 Manuel d'utilisation

Page 9

Advertising
background image

EN

9

9

Mounting the hood body

• Before attaching the hood body, tighten the two screws Vr lo-

cated on the hood body mounting points.

• Hook the hood body onto the screws 12a.
• Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body.



Note: The Hood body should be secured to wall studs. If neces-
sary, install a wood support behind the dry wall, flush mounted
between 2 studs. This will provide the necessary structure and
support for mounting.

12a

Vr

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chim-
ney using a rigid 6” duct.

• Install the damper 10 ø 6”.
• Fix the duct in position using sufficient pipe clamps (not sup-

plied).

10

DUCTLESS VERSION AIR OUTLET

• Put connection 15 into the connection support 7.3.
• Insert the connection extension pieces laterally 14.1 in connec-

tion 15.

• Make sure that the outlet of the extension pieces 14.1 is hori-

zontally and vertically aligned with the chimney outlets.

• Connect the air outlet connection 15 to the hood body outlet

using a rigid ø 6” duct. (not supplied)

• Ensure that the activated charcoal filters have been inserted.

14.1

15

Advertising