3. Remove the cover from the field wiring compartment.

Remove the wiring electrical knockout using a flat-blade

screwdriver. Feed the Power Supply Cable through the

electrical knockout.

4. Rotate the two adjustment screws ( R in FIGURE 8 )

until inserted halfway in the slot. Hang the canopy on the

bracket. The canopy hangs from the flanges on the lower

bracket. Due to the weight of the canopy, two people should

lift it to avoid injuries. Make sure that the tabs are fully inserted

into the slots and that the canopy is secure on the bracket.

5. The height of the canopy can be adjusted by rotating

the two screws (R) indicated in FIGURE 8. These are also

used to insure that the canopy is level.

Version 11/00 - Page 6

FIGURE 8

6. Connect the Power Supply Cable to the rangehood.

Attach the White lead of the power supply to the White lead

of the rangehood with a twist-on type wire connector. Attach

the Black lead of the power supply to the Black lead of the

rangehood with a twist-on type wire connector. Connect the

Green ( Green and Yellow ) ground wire under the Green

grounding screw.

7. If your installation uses a remote blower, connect the wir-

ing cable for the remote blower. DO NOT connect the remote

blower to the Power Supply Cable. The wiring diagram for this

rangehood is supplied next to the Use and Care Information

on the rear of the Installation Instructions.

8. Replace the field wiring compartment cover and the

grease filters

For ductless installations:

Ductless installations require a ductless kit. This kit consists

of alower chimney cover with holes for the exhaust air, a

ductless diverter, two grids to cover the holes in the chimney

cover, two charcoal filters. The ductless diverter must be

installed before the lower chimney cover is attached as in

FIGURE 9. The lower chimney cover without holes should

be discarded. Once the lower chimney cover with holes is

installed, the grids are inserted into the holes as illustrated

in FIGURE 10.

FIGURE 9

FIGURE 12

FIGURE 10

9. For ducted installations, the damper must be attached

to the exhaust opening on the top of the canopy. Two small

phillips screws are provided with the damper to attach it to

the canopy. Connect the ductwork and seal all connections

with duct tape.

10. The chimney must be attached to the body of the

rangehood. The upper section of the chimney (S) must be

installed first, then the lower section (I). Both sections are

secured to the wall under the mounting brackets as indicated in

FIGURE 11. Once the chimney is in the final position, screws

are used to secure the top and bottom of the chimney to the

brackets.

FIGURE 11

11. Turn the power supply on. Turn on blower and light.

The rangehood controls are located in a gray panel on the

canopy's underside. To open the panel, press up on the

front edge and release as indicated in FIGURE 12. If the

rangehood does not operate, check that the circuit breaker

is not tripped or the house fuse blown. If the unit still does

not operate, disconnect the power supply and check that the

wiring connections have been made properly.