INSTALLATION DIMENSIONS

The Nova chimney is adjustable and designed to meet varying

ceiling heights. FIGURE 2 illustrates the standard installa-

tion for the Nova which requires the canopy to be mounted

24" above the countertop. The chimney can be adjusted for

ceilings between 8 feet and 9 feet.

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

• 1 Hardware Package

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• Wiring Cable - Optional Remote Blower Only

• 1 Wall or Roof Cap

• All Metal Ductwork

RANGEHOOD ASSEMBLY

B -

C -

S -

I -

1 -

2 -

3 -

OPTIONAL BACKSPLASH

CANOPY

UPPER CHIMNEY

LOWER CHIMNEY

LOWER BRACKET

UPPER BRACKET

MIDDLE CHIMNEY BRACKET

FIGURE 1

FIGURE 2

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 35 feet if ducted with 3 1/4"

by 10" rectangular duct and 60 equivalent feet if ducted with

9" round ductwork. Calculate the length of the ductwork by

adding the equivalent feet in FIGURE 3 for each piece of duct

in the system An example is given in FIGURE 4. For best

results, use no more than three 90° elbows. Make sure that

there is a minimum of 24" of straight duct between elbows if

more than one is used. Do not install two elbows together.

Remote blowers require 9" round duct.

WARNING

Because of the weight and size of the rangehood

canopy, two or more people are needed to move

and safely install the rangehood canopy.

Failure to properly lift rangehood could result in

damage to the product or personal injury.

PERSONAL INJURY HAZARD

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap

Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 4

7.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 3

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or ductless.

The blower can be vented through the wall or ceiling. To

vent through a wall, a 90° elbow is used. When installed

ductless, the rangehood vents out of grates on the sides of

the chimney. Ductless installations require a Ductless Kit,

available from your dealer.

This rangehood can be used with an optional remote blower.

If a remote blower is used, then the internal blower must be

removed and discarded. Both blowers cannot be used together.

The remote blower connects to the rangehood using a separate

wiring cable not supplied with the rangehood. The wiring cable

should be installed at the same time as the ductwork.

WARNING! BEFORE MAKING ANY CUTS OR HOLES

FOR INSTALLATION, DETERMINE WHICH VENTING

METHOD WILL BE USED AND CAREFULLY CALCULATE

ALL MEASUREMENTS.

9 1/2"

Min. - 1"

Max. - 20"

upper

chimney

cover

22"

cabinet

base

24"

36"

lower

chimney

cover

canopy

Min. 92 1/2"

Max. 111 1/2"

19 1/4"

!