ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

H

G

F

L

Figure 2 – COUNTERTOP CUTOUT OPENING

CAUTION

to eliminate the risk of burns

or fire resulting from reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5" (12.7
cm) beyond the bottom of the cabinets.

Letters on this figure refer to chart on front page except for J, K & L.

Overhead Cabinet

Should Not exceed a

Maximum Depth of

13" (33 cm)

30" (76.2 cm) Min.

Clearance Between the

top of the Cooking

Platform and the Bottom

of an Unprotected Wood

or Metal Cabinet

24" (61 cm) Min.

when Bottom of Wood

or Metal Cabinet

is Protected by Not

Less than 1/8" Flame

Retardant Millboard

Covered With Not Less

than No. 28 MgS Sheet

Steel, 0.015" (0.4 mm)

Stainless Steel, 0.024"

(0.6 mm) Aluminum or

0.020" (0.5 mm) Copper

2 1/2" (6.4 cm) Min. From

edge of Cutout to Front edge

of Countertop

Approximate Location

of Junction Box

18"

(45.7 cm)

For a drawer installation

below the cooktop, allow

8"(20.4cm) of clearance

underneath the countertop.

the drawer must not interfere

with the electrical installation

of the cooktop or contain

flammable materials.

J

Min. From

edge of

Cooktop

to Nearest

Combustible

Wall (either

Side of Unit).

12"

(30.5 cm)

10"

( 25.4 cm)

Min.

K

Min.

Recommended

Distance Between

Rear edge of

Cutout and Nearest

Combustible

Surface Above

Countertop

24"

(61 cm)

MODEL

J

K

L

30’’ Ceramic glass

7 ½’’ (19.1 cm)

2’’ (5.1 cm)

30" (76.2 cm)

36’’ Ceramic glass

7 ½’’ (19.1 cm)

2’’ (5.1 cm)

36" (91.4 cm)