INSTALL THE HOOD

Fix the hood to the support frame with (6) 3.9x9.5mm mounting screws and (2)

serrated washers.

CONNECT DUCTWORK

(DUCTED HOODS ONLY)

1. Use 6" round metal duct to connect the discharge collar on the hood to the

ductwork above.

2. Use duct tape to make all joints secure and air tight.
3. Remove the temporary retaining screw from the lower flue and set it in place on

the hood.

6” ROUND METAL

DUCT

RETAINING

SCREW

FIG.13

FIG.14

MOUNTING SCREWS

(3.9x9.5mm)

SERRATED

WASHERS

INSTALL FILTERS

(DUCTED AND NON-DUCTED HOODS)

1. To remove the GREASE filter, push in on the metal latch tab and tilt filter

downward to remove.

2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress

the metal latch tab, push filter into position and release. Make sure filter is

securely engaged after installation.

NOTE: Prior to use, remove protective film from the filter frame.

(NON-DUCTED HOODS ONLY)

1. To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter

down to disengage the rear filter tabs.

2. To install the CHARCOAL filter, align the rear filter tabs with slots in the hood.

Push the filter up into place until the front latch snaps securely into the slot.

Make sure the filter is securely engaged after assembly.

3. Install GREASE filter after charcoal filter is installed.