Faber Agio Manuel d'utilisation

Page 6

Advertising
background image

Version 10/05 - Page 6

6. Reattach the control box and support. Make sure that

the wiring harness is concealed behind the support.

7. Remove the field wiring compartment cover. Feed the

Power Supply Cable through the electrical knockout.

8. Attach the backdraft damper to the proper exhaust open-

ing using two silver screws supplied with the rangehood.

9. Attach the rangehood to the cabinet bottom. The four

key holes slip onto the four screws mounted to the cabinet

bottom. Tighten the screws.

10. Connect the Power Supply Cable to the rangehood.

Attach the White lead of the power supply to the White lead

of the rangehood with a twist-on type wire connector. Attach

the Black lead of the power supply to the Black lead of the

rangehood with a twist-on type wire connector. Connect

the Green (Green and Yellow) ground wire under the Green

grounding screw.

3. For ductless installations, Charcoal Filters are required

and must be installed before the grease filters are replaced.

The charcoal filters attach to both ends of the blower as

indicated in FIGURE 14.

4. Remove the central support and control box by remov-

ing the screws indicated in FIGURE 11. It is not necessary

to remove the blower to perform this operation.

5. Attach the cover behind the exhaust grate with two silver

screws supplied with the rangehood as indicated in FIGURE 12.

11. Replace the field wiring compartment cover. For duct-

less installations, refer to the next section which discusses

ductless installations. Replace the grease filters.

12. Turn the power supply on. Turn on blower and light.

IF THE RANGEHOOD DOES NOT OPERATE:

• Check that the circuit breaker is not tripped or the

house fuse blown.

• Disconnect the power supply and check that the

wiring connections have been made properly.

DUCTLESS INSTALLATIONS

For ductless installations, the blower must be positioned with

the exhaust pointing forward ( so that the exhaust exits from

the front grill ) before attaching the rangehood to the cabinet.

Ductless installations require Charcoal Filters.

1. Remove both grease filters, the central support and the

control box. Remove the two thumb screws on either side of

the blower and remove the blower from the mounting guides

as indicated in FIGURE 11.

2. Rotate the blower 180° so that the exhaust points out

the front of the rangehood. Replace the two thumb screws

and tighten so that the blower is securely fastened inside the

rangehood as indicated in FIGURE 13. Reattach the control

box and central support. Make sure that the wiring harness

is concealed behind the central support.

FIGURE 10

FIGURE 11

FIGURE 12

FIGURE 14

FIGURE 13

Advertising