TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape
PARTS SUPPLIED FOR INSTALLATION

• 1 Backdraft Damper

• 4 Black Screws & 4 Silver Screws

• 1 Literature Package
PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE

Charcoal Filters

For non-vented installations only,

replace charcoal filters as needed

part # 6093032

PLAN THE DUCTWORK

The Agio convertible rangehood is designed to offer wide

flexibility of installations. The rangehood can be ducted

vertically or horizontally through a 3 1/4" X 10" rectangular

vent. The unit can also be installed in a ductless recirculating

configuration. FIGURES 1 and 2 show horizontal and vertical

duct installations for this rangehood. FIGURE 3 shows the

exhaust opening for ductless installation.

HORIZONTAL

DUCTING

VERTICAL

DUCTING

DUCTLESS

INSTALLATION

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 25 equivalent feet if ducted with the

required minimum of 3 1/4" by 10" rectangular duct. Calculate the

length of the ductwork by adding the equivalent feet in FIGURE 4

for each piece of duct in the system. An example is given in FIGURE

5. For best results, use no more than three 90° elbows. Make

sure that there is a minimum of 24" of straight duct between

elbows if more than one is used. Do not install two elbows

together. If you must elbow right away, do it as far away from

the hood's exhaust opening as possible.

FIGURE 4

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow
Wall Cap

3.0 feet

5.0 feet

12.0 feet

0.0 feet

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 5

PLAN THE DUCTWORK

First, determine which venting option will be used:

• Horizontal

• Vertical

• Ductless

For Horizontal and Vertical ducting, the ductwork cutout dimensions

are given in FIGURE 6. For ductless installations, read the section

discussing ductless installations before you make any cutouts or

modifications to the rangehood. Ductless installations require

Charcoal Filters.

FIGURE 6

30" or 36" or 23 5/8" (60 cm)

30" or 36" or 23 5/8" (60 cm)

FIGURE 1

FIGURE 2

FIGURE 3

Pre-Planning Your Installation - Important: The

recommended height to install this hood off the cooktop

is a minimum of 24" and a maximum of 30” for maximum

effectiveness. Also consult the cooktop manufacturerʼs

recommendation.